+86 18068001229 01
35MVA 115kV Transformer Ike nke Usoro 3
Nkọwa Ngwaahịa
Transformer Ike nke Usoro 3 nke 35MVA 115kV, bụ ngwaọrụ eletriki ọgbara ọhụrụ nke e mere iji jee ozi dị mkpa na ọrụ ike mmeghari ohuru. E wuru ya ka o ruo n'ọkwa kachasị elu nke arụmọrụ, ntụkwasị obi, na arụmọrụ ike, na-ahụ na arụmọrụ kacha mma na sistemụ ike ọdịnala na nke mmeghari ohuru.
Isi Atụmatụ & Arụmọrụ
Nrubeisi na IEEE C57.12.00: Transformer nke 35MVA 115kV na-agbaso ụkpụrụ ụlọ ọrụ mba ụwa, na-ahụ na ọ dị mma ma na-arụ ọrụ nke ọma.
Mfu dị ala na arụmọrụ dị elu: E mere ya ka ọ ghara inwe isi na ọla kọpa, transformer a na-ebelata oke oriri ike, na-eme ka ọ dịgide ma na-ebelata ọnụ ahịa ya.
Mbelata Mwepụ na Mkpọtụ Akụkụ: E mepụtara ya maka obere mwepụ akụkụ (PD) na mwepụ mkpọtụ, ọ na-eme ka ọrụ dị jụụ ma na-eme ka ọ kwụsie ike ogologo oge.
Nguzogide Gburugburu Dị Mfe: E mere transformer ahụ ka ọ nagide nsogbu dị elu, na-eme ka nchekwa na ịdịte aka nke sistemụ ahụ ka mma.
Nhazi Na-enweghị Ntapụ Mmiri: Site na owuwu siri ike, e mere transformer a iji gbochie ntapu mmanụ, na-eme ka nchekwa gburugburu ebe obibi na ntụkwasị obi sistemụ dịkwuo mma.

35MVA 115kV Transformer Power
Ihe na Mwube Dị Elu
1. Ihe Ndị Dị n'Ime na Ihe Ndị Dị n'Ime: Ejiri ígwè silicon dị elu, nke na-adịgide adịgide, rụọ isi ihe transformer ahụ, nke nwere usoro njikọta steepụ dị elu na 45° maka ikuku magnetik kacha mma. A na-ekpuchi elu ya na oyi akwa pụrụ iche nke na-egbochi mmebi, na-ebelata mfu na-enweghị ibu ma na-ebelata ọkwa mkpọtụ.
2. Mkpọtụ Dị Ala na Ịdịgide Ka Mma: Nchikota eriri na isi gụnyere atụmatụ imewe nkeonwe dịka ihe nkwado isi na iji waya ndị na-eduzi ihe, na-eme ka mmepụta mkpọtụ dị obere ma kwụsie ike ogologo oge.
Ihe Mgbanwe Mkpọchi N'elu Ibu (OLTC)
1. E tinyere ihe mgbanwe 35MVA nke nwere On-Load Tap Changer (OLTC) n'akụkụ voltaji dị elu, nke na-enye ohere maka nhazi voltaji n'etiti 115kV ± 8 × 0.625%.
2. OLTC gụnyere ihe nchekwa, ihe ngosi ọkwa mmanụ, ihe eji agbagharị Buchholz, na ihe na-eku ume nke na-eme ka transformer ahụ dịghachi ndụ, ihe niile na-enyere aka na ọrụ nchekwa na nkwụsi ike nke transformer ahụ.
Atụmatụ Nchedo na Nchekwa
1. Nchekwa Gas na Differential: E tinyere transformer ahụ na nchekwa gas na relay nchedo differential iji hụ na arụ ọrụ dị mma yana nchọpụta mmejọ n'oge.
2. Nlekota Relay: Ngwaọrụ a nwere relays dị n'ime na nke dị n'èzí nke na-akpali mkpu ma na-amalite ịda ada na akpaghị aka ma ọ bụrụ na achọpụta mgbanwe gas ma ọ bụ mmanụ na-adịghị mma.
3. Nlekota Ọkwa Mmanụ: Ihe ngosi ọkwa mmanụ na-enyocha ọnọdụ tankị mmanụ, na-akpali mkpu ma ọ bụrụ na ọkwa mmanụ ada n'èzí oke akọwapụtara, na-ahụ na mmezi mmanụ kacha mma.
Nrụgide Mgbochi Valvụ
Ọ bụrụ na gas dị n'ime ahụ agbawa ngwa ngwa n'ihi nsogbu dị na ya, a na-etinye transformer ahụ na valvụ enyemaka nrụgide. Sistemụ a na-ewepụta gas gabigara ókè, na-egbochi nrụgide gabigara ókè ma na-enye ohere ka ụlọ njikwa mee ihe ozugbo site n'ịkpalite njem akpaka.
Nlekota Okpomọkụ
Ihe ngosi okpomọkụ mmanụ na ikuku: Transformer ahụ nwere ihe mmetụta iji nyochaa okpomọkụ mmanụ na ikuku. Ọ bụrụ na okpomọkụ karịrị 95°C, a na-eziga mgbaàmà mkpu na ụlọ nlekota anya dị anya. Ọ bụrụ na okpomọkụ karịrị 105°C, transformer ahụ ga-ada ada na akpaghị aka iji gbochie oke okpomọkụ na mmebi nwere ike ime.
Sistemụ Jụụ
Transformer nwere sistemụ oyi nke nwere ogbo abụọ:
Nkebi nke 1: Fan oyi mbụ na-arụ ọrụ mgbe okpomọkụ ikuku gafere 75°C.
Nkeji nke Abụọ: Fan nke abụọ na-arụ ọrụ mgbe okpomọkụ ruru 80°C.
Mgbe okpomọkụ dara n'okpuru 75°C, ndị fan na-agbanyụ na akpaghị aka, na-eme ka ọ dị jụụ nke ọma ma na-ebelata oriri ike.
Ihe na-eku ume nke na-eme ka onwe ya dịghachi ndụ
Ma isi ahụ nke transformer na ihe nchekwa tap changer nwere ihe na-eku ume nke na-emegharị onwe ya (ụdị Qualitrol). Ihe na-eku ume na-eji ihe na-eme ka mmiri dịghachi ndụ (silica gel) nke na-amịkọrọ mmiri ma na-eme ka ọ dịghachi ndụ site na ikpo ọkụ, na-egbochi mmiri na ikuku ịbanye na transformer. Nke a na-eme ka mkpuchi ahụ ghara ịka nkụ, na-akwado nkwụsi ike ọrụ ogologo oge nke transformer.
Ngwa
1. Ọrụ Ike Mmeghari ohuru (Anyanwụ, Ifufe, wdg)
2. Nkesa Ike Ụlọ Ọrụ
3. Nkwụsi ike na Grid
4. Sistemụ Ike Dị Elu nke A Pụrụ Ịtụkwasị Obi

Mmechi
Transformer Ike nke Usoro Atọ nke 35MVA 115kV bụ ngwọta kachasị ọhụrụ ma dị elu maka sistemụ nkesa ike ọgbara ọhụrụ, ọkachasị na ngalaba ike mmeghari ohuru. Site na ihe ndị dị elu, atụmatụ nchekwa dị elu, na imewe nchekwa ike, ọ na-enye arụmọrụ dị elu, ntụkwasị obi, na ndụ ọrụ ogologo. Ngwaahịa a na-egosi nkwa JZP Transformer n'inye ngwọta ọhụrụ na nke dị mma iji mezuo ihe achọrọ nke ọdịnihu ike na-adịgide adịgide.
Ịdị Njikere Ime Ka Ọdịnihu Ike Dị Ike?
Kpọtụrụ anyị taa ka ịmatakwu gbasara otu 35MVA 115kV Three-Phase Power Transformer nwere ike isi mee ka ọrụ ike mmeghari ohuru gị ka mma ma hụ na nkesa ike a pụrụ ịtụkwasị obi ma dị irè.

Jụọ ajụjụ ugbu a!
Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.