+86 18068001229 01
Transformer nke nwere otu usoro—15KVA
Nkọwa Ngwaahịa
JZP Transformer bụ ọkachamara n'ịmepụta transformers 15 kVA nke nwere otu usoro poolu nke na-agbaso ụkpụrụ mba ụwa kachasị elu, gụnyere IEEE C57.12.00, IEEE C57.12.20, DOE-2016 Arụmọrụ Dị Mkpa, CSA C2.1 & C2.2, na CSA C802.1. N'ịbụ ndị a na-akwali site na nkwa siri ike maka ịdị mma, anyị na-enye ngwọta ahaziri iche nke e mere ka ha kwekọọ kpọmkwem na nkọwapụta teknụzụ pụrụ iche gị.
N'agbanyeghị ọkwa voltaji ma ọ bụ gburugburu ọrụ ị chọrọ, tụkwasị JZP Transformer obi inye azịza kacha mma dabara na mkpa gị. Afọ ojuju gị, tinyere ntụkwasị obi na-enweghị mgbagha nke transformers anyị, ka bụ isi ihe dị mkpa n'inye anyị ọrụ dị mma.
Iji hụ na usoro nnyefe dị mfe ma dị ọnụ ala, anyị ahaziela ma tinye transformers niile nke ọma ka ha dabara nke ọma n'otu akpa 40HQ, na-eme ka usoro njem dịkwuo mfe ma na-ebelata mmefu njem niile.
Site n'ịhọrọ transformers JZP, onye ahịa nwere ike inwe obi ike na mkpebi ha itinye ego na ngwa eletriki kachasị elu, na-ekwe nkwa arụmọrụ na nchekwa ike na-enweghị atụ. Nkwa a maka arụmọrụ na nkwado na-adaba na ebumnuche anyị iji tinye aka na mpaghara ike na-acha akwụkwọ ndụ akwụkwọ ndụ na nke nwere ọrụ.
Transformer nke e ji osisi rụọ 15kVA 21.6kV
Na-ewebata DL-15/21.6/0.24(0.12), transformer dị elu nke nwere otu usoro 15 kVA nke e ji osisi rụọ nke ọma, nke JZP Transformer mepụtara nke ọma ma jiri nganga mee. Transformer a na-emezu ụkpụrụ siri ike nke IEEE Std C57.12.00 na IEEE Std C57.12.20, na-ahụ na arụmọrụ na nchekwa pụrụ iche dị.
Site na ọkwa voltaji dị elu nke 21.6 kV na ọkwa voltaji dị ala nke 240V (120V), DL-15/21.6/0.24(0.12) na-agbanwe ike nke ọma iji mezuo ọtụtụ ọrụ. Nhazi voltaji ya sara mbara sitere na 21600V ruo 22680V na-ekwe nkwa mmepụta voltaji na-agbanwe agbanwe ma kwụsie ike, na-eme ka arụmọrụ a pụrụ ịdabere na ya ọbụlagodi n'okpuru ibu na-agbanwe agbanwe.
Iji nye mkpuchi siri ike na nchekwa, transformer ahụ nwere BIL (Ọkwa Mkpuchi Isi) nke 125 kV maka voltaji dị elu na 30 kV maka obere voltaji, na-echebe megide mmụba eletriki ma na-ahụ na ọ na-adịgide adịgide.

Transformer 14.4kV nke e ji osisi rụọ
N'iwebata JZP-15/14.4(24.94)/0.24(0.12), transformer nke nwere otu ogidi 15 kVA nke JZP Transformer mepụtara ma rụpụta ya n'ụzọ dị egwu.
Nwere nnukwu voltaji nke 14.4 kV na obere voltaji nke 240V (120V), ọkwa ike 15 kVA. DL-15/14.4(24.94)/0.24(0.12) na-eme ka mgbanwe voltaji dị irè ma dịkwa mma iji mezuo ihe dị iche iche achọrọ maka ike. Ma windings dị elu na nke dị ala bụ nke ejiri aluminom siri ike rụọ, na-eme ka arụmọrụ dị elu ma dị ogologo.
Emebere transformer ahụ site na iji polarity agbakwunyere, na-ahụ na enwere ike ijikọ ya nke ọma ma melite ọrụ ya na sistemụ nkesa ike gị.
Site na oke nhazi voltaji nke 13680V ruo 15120V, transformer a na-ekwe nkwa mmepụta voltaji kwụsiri ike ma na-agbanwe agbanwe, na-enye arụmọrụ kachasị mma n'okpuru ọnọdụ ibu dị iche iche. BIL ya dị egwu (Ọkwa Mkpuchi Isi) nke 95 kV na 30 kV na-eme ka nchebe siri ike megide mmụba eletriki, na-eme ka ntụkwasị obi na nchekwa nke transformer dịkwuo mma.

Transformer 14.4kV nke e ji osisi rụọ
Mmiri mkpuchi eji eme ihe bụ mmanụ mineral dị elu, enweghị PCB, na-akwalite ọrụ nchekwa na nke na-adịghị ize ndụ gburugburu ebe obibi. Sistemụ oyi ahụ na-eji usoro ONAN (Mmanụ Natural Air Natural) eme ihe, na-ewepụ okpomọkụ nke ọma ma na-eme ka transformer ahụ rụọ ọrụ nke ọma.
Ọzọkwa, transformer nke 15kVA 14.4 kV nwere bushings abụọ dị elu na bushings atọ dị ala, na-enye nhọrọ njikọ dị mfe. A na-eme ka bushings ndị dị ala na-agbakwụnye site na iji ogwe ọla kọpa na-eme ka ha dị mma, na-eme ka nchekwa dịkwuo mma n'oge ọrụ.
Maka ngwa atọ, enwere ike ijikọta transformers atọ nke nwere otu usoro 14.4 kV iji nye ike na 24.94 kV, na-egbo mkpa nke ọtụtụ ntọala ụlọ ọrụ mmepụta ihe na ọrụ.

Transformer 15kVA 7.2kV nke e ji osisi rụọ
N'iwebata DL-15/7.2(12.47)/0.24(0.12), bụ transformer nke JZPTansor mepụtara ma rụpụta, nke nwere otu ogidi. Transformer a nwere ikike siri ike nke 15 kVA, nke mere ka ọ dị mma maka ọtụtụ ọrụ. Site na ọkwa voltaji mbụ nke 7.2 kV (12.47 kV) na ọkwa voltaji nke abụọ nke 120V (240V), transformer a na-eme ka mgbanwe voltaji dị irè iji mezuo ihe dị iche iche achọrọ maka ike.
Iji kwado njikọ na ngwa dị iche iche, DL-15/7.2(12.47)/0.24(0.12) nwere ihe mkpuchi voltaji abụọ dị elu na ihe mkpuchi voltaji atọ dị ala, nke nwere atụmatụ ntọala voltaji dị ala maka nchekwa ka mma.
Site na oke nhazi voltaji dị iche iche nke sitere na 6840V ruo 7560V, transformer a na-ekwe nkwa njikwa voltaji a pụrụ ịtụkwasị obi na nke na-agbanwe agbanwe, na-ahụ na nkesa ike kwụsiri ike n'ofe ibu dị iche iche. Ọzọkwa, DL-15/7.2(12.47)/0.24(0.12) na-egosipụta ọtụtụ ihe dị iche iche, ebe ọ bụ na transformers atọ nke imewe a nwere ike ijikọ ngwa ngwa iji mepụta transformer 12.47 kV nke usoro atọ, na-enye ọtụtụ ngwa ụlọ ọrụ na nke ọrụ.

Transformer nke e ji osisi rụọ 15kVA 19.2kV
DL-25/19.92/0.24(0.12), bụ transformer pụrụ iche nke nwere otu usoro 15 kVA, nke JZP Transformer mepụtara n'anya, ma na-agbaso ụkpụrụ siri ike nke IEEE C57.12.20 na ANSI C57.12. Emebere transformer a iji nye arụmọrụ na ntụkwasị obi dị elu, na-emezu mkpa dị iche iche nke sistemụ nkesa ike nke oge a. Transformer 15kVA nwere depolarization ma na-eji otu vector IIo, na-ahụ na ọ na-arụ ọrụ nke ọma na nke na-enweghị nsogbu, ma na-eme ka arụmọrụ na nkwụsi ike zuru oke na netwọk nkesa.

Akụkọ Nnwale Transformer nke e tinyere n'elu 10kVA
Na JZP Transformer, ịdị mma dị n'ihu n'usoro mmepụta anyị. Transformer ọ bụla e tinyere n'elu ogidi na-eme nnwale siri ike ma zuru oke tupu ọ pụọ n'ụlọ ọrụ mmepụta anyị. Anyị na-agbaso usoro njikwa mma siri ike iji hụ na transformer ọ bụla ruru ụkpụrụ kachasị elu n'ụlọ ọrụ ma gafere atụmanya ndị ahịa.
N'oge ule a na-eme kwa ụbọchị, ndị ọkachamara anyị nwere nkà na-enyocha ma na-enyocha arụmọrụ nke transformer ahụ nke ọma, nchekwa, na ntụkwasị obi ya. A na-enyocha paramita ndị dị mkpa dịka iwu voltaji, mgbochi mkpuchi, mfu ibu, enweghị mfu ibu, na mgbochi iji chọpụta na transformer ahụ arụghị ọrụ nke ọma.
Naanị mgbe anyị gafere ule siri ike nke ọma ma mezuo ihe niile achọrọ maka ịdị mma, a na-ewere transformer dị ka onye ruru eru maka nkwakọ ngwaahịa na mbupu. Usoro a nke ọma na-eme ka ndị ahịa anyị na-enweta naanị transformer kacha mma na nke kacha nwee ntụkwasị obi nke dabara na mkpa ha kpọmkwem.

Jụọ ajụjụ ugbu a!
Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.








