Leave Your Message

Transformer nke a na-etinye n'ime usoro atọ nke 2000kVA

Ọkwa Voltaji Mbụ: Delta 34500
 Ọkwa Voltaji nke Abụọ: 480Grdy/277
ỤDỊ NJIKỌTA: Dyn1
ỤDỊ: Ihe nkwado pad nke atọ
BỤ: 150/30
Ụkpụrụ: ANSI, IEEE, NEMA
 Ngwa: Ike Inyeaka Nchekwa Ike Batrị
 Ọkwa Ike: 2000kVA
 Asambodo: UL
Usoro oyi: Debe obi iru ala ma hụ n'anya

    Nkọwa Ngwaahịa

    A na-etinye transformers JZP Transformer nke nwere ike 2000kVA, 34.5kV n'ime Sistemụ Nchekwa Ike Batrị (BESS) na Kern County, California, ebe ha na-enye ike enyemaka a pụrụ ịdabere na ya iji kwado ngwaọrụ dị iche iche n'ime ọdụ nchekwa ike. Emechara ya na Mee 2024 ma nyefee ya nye ndị ahịa Amerịka, transformers ndị a dị mkpa iji hụ na ọrụ na-aga n'ihu na njikwa nchekwa ike dị irè.
    asambodo01
    asambodo02
    asambodo03
    asambodo04
    asambodo05
    asambodo06
    asambodo07
    asambodo08
    asambodo09
    01020304050607
    Okpomọkụ gburugburu ebe obibi Nke kacha nta -15.0°C, Oke kachasị 41.0°C, nkezi kacha elu awa 24 33.0°C
    Mbuli elu
    Ọnọdụ ala ọma jijiji: Ụdị Ihe Ize Ndụ: II, Klas saịtị D
    SS = 1.28 g, S1 = 0.43 g, SMS = 1.54 g, SM1 = 1.09 g, SDS = 1.03 g, SD1 = 0.73 g
     
    Ọrụ nkịtị (site na nkeji ruo na nkeji) 34.5kV
    Ọrụ kachasị elu (otu-site-na-phase) 38kV
    Nhazi ịgbagharị Delta
    Ọkwa Bushing 600A
    Mkpuchi ikuku 200kV BIL
    Mkpuchi Bushing 200kV BIL
    Ọnụọgụ Bushing Isii (Nri Mgbapụ)
    Mgbochi sekit dị mkpirikpi 30kA
    Kwụpụ Mgbanwe LBOR
    Kwụpụ ọnụọgụ mgba ọkụ Otu (1) Usoro nke atọ
    Ọrụ nkịtị (site na nkeji ruo na nkeji) 480V
    Nhazi ịgbagharị Wye e ji ájá mee
    Mkpuchi windo na nke bushing BIL Ụgbọala 30KV
    Mgbochi sekit dị mkpirikpi 65 kA*
    Oghere spade LV nke dị n'ime oghere (8) NO oghere abụọ
    Ihe na-akpata oke voltaji kwa ụbọchị 110%
    Nguzogide dabere na ntọala Mba
    Bọs ala Ee
    Voltaji ọkọnọ sekit njikwa 277V AC
    Nkọwapụta nke mgbawa sekit Edepụtara UL
    Dabara adaba maka ọnụ ụzọ ọrụ Ee
    Nha (n'ime) W*D*H: 83.9*94.7*95.3
    Tankị na Ngwa 4,630lbs
    Mmanụ dị oke ibu 900Gal
    Mkpokọta Ibu 21,600lbs

    Atụmatụ na Uru Ndị Dị Mkpa
    Nkesa Ike Dị Irè Maka Nchekwa Ike
    Emebere transformers 2000kVA ka ha gbadaa site na etiti voltaji (MV) gaa na obere voltaji (LV), na-eme ka ha dị mma maka ijikọ na switchboards na sistemụ nchekwa ike. Nhazi stepdown a dị mkpa iji hụ na nkesa ike dị nro ma dị mma nye akụrụngwa enyemaka, na-akwado arụmọrụ zuru oke nke akụrụngwa BESS.

    Ịdịgide na Nchekwa Dị Ọnụego
    Dịka nkwa JZP Transformer siri dị maka nkwado siri ike, ndị transformer na-eji mmanụ a na-ere ere eme ihe dị ka mmiri oyi. Ngwọta a na-adịghị emerụ gburugburu ebe obibi anaghị enye naanị ihe mkpuchi dị elu kamakwa ọ na-akwado arụmọrụ ike.

    Ịdịgide na Nchekwa E wuru n'ime ya
    Ihe mkpuchi NEMA 3R: A na-etinye transformers anyị n'ime ihe mkpuchi eletriki NEMA 3R nke mmiri na-anaghị ezo, na-anaghị ajụ oyi, na-anaghịkwa ajụ oyi, yana ihe nchekwa mmiri dị n'ime ya. Ihe mkpuchi ndị a na-enye nchebe siri ike megide ihe ndị dị n'ime ya, na-echebe ihe ndị dị n'ime ya ma na-eme ka ọ dịgide ogologo oge ọbụlagodi n'ọnọdụ gburugburu ebe obibi siri ike.
    Atụmatụ Mgbochi Mmebi na Nchekwa: E mere ya ka ọ bụrụ nchekwa n'uche, transformers ndị a nwere usoro mkpọchi na mkpọchi ọzọ iji gbochie ohere na mmebi ikike na-enweghị ikike, na-ebelata ihe egwu nke izu ohi ma na-ahụ na ọrụ dị nchebe n'oge niile.
    Nhazi dị mfe iji maka nchekwa na arụmọrụ
    Akụkụ obere voltaji nke transformer ahụ nwere imewe pụrụ iche nke etinyere n'akụkụ ya nke nwere akpịrị maka njikọ dị mfe na switchboard. A na-etinye ihe nlele, valvụ ihe nlele, na sistemụ drainage ndị a na-etinye n'èzí n'ime kabinet a na-akpọchi akpọchi nke nwere mkpọchi bolt isi ise. Nhazi pụrụ iche a na-enye ndị ọrụ ohere inyocha ọkwa mmanụ n'enweghị nsogbu, nwalee ihe nlele ahụ, ma rụọ ọrụ mmezi na-ekpughe onwe ha na bushings dị elu (HV) ma ọ bụ obere voltaji (LV), nke na-eme ka nchekwa na arụmọrụ ọrụ dịkwuo mma.
    Atụmatụ na Uru Ndị Dị Mkpa

    Nha mpụta nke transformer arụnyere na pad
    Nlekota di elu na Ndọ aka ná ntị dị anya
    Iji hụ na arụmọrụ ya na-aga n'ihu, nke kacha mma, transformer nwere ihe ngosi ọkwa mmanụ na okpomọkụ nke nwere ebe kọntaktị abụọ maka nlekota anya n'ebe dị anya. Ihe ngosi ndị a na-enye ndị ọrụ data ozugbo, na-eziga ihe mgbaàmà mkpu mgbe ọkwa mmanụ dị oke elu ma ọ bụ dị ala. Na mgbakwunye, ọ bụrụ na okpomọkụ nke mmiri oyi gafere 85°C, sistemụ ahụ ga-akpali mkpu. Ọ bụrụ na okpomọkụ ebili karịa 105°C, transformer ga-apụ na grid na akpaghị aka iji gbochie oke okpomọkụ na mmebi nwere ike ime, na-ahụ na nchekwa na ntụkwasị obi nke sistemụ ahụ.
    ihe nlele mpụga nke transformer arụnyere na pad

    Ịdị mma na Nrubeisi
    A na-emepụta Transformers JZP n'ụzọ siri ike na ụkpụrụ ndị bụ isi nke ụlọ ọrụ mmepụta ihe, gụnyere UL, ANSI, IEEE, na NEMA, na-ahụ na arụmọrụ, ntụkwasị obi, na nchekwa dị elu. Nkwa anyị nwere maka ịdị mma na ihe ọhụrụ na-ekwe nkwa na e wuru transformer ọ bụla ka ọ dabara na nkọwapụta kachasị elu, na-enye ọrụ a pụrụ ịtụkwasị obi n'oge ndụ akụrụngwa ahụ.
    Ịdị mma na Nrubeisi

    Jụọ ajụjụ ugbu a!

    Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.

    Leave Your Message