Leave Your Message

69kV 4200kVA 5250kVA Transformer Ike nke Usoro Atọ

Ọkwa Voltaji Mbụ: 110kv, 115kv, 121kv ma ọ bụ ndị ọzọ
Ọkwa Voltaji nke Abụọ: 11/10.5/6.6/6.3kV ma ọ bụ ndị ọzọ
Oke Mkpọtụ HV: ±8 × 1.25% ma ọ bụ ndị ọzọ
ỤDỊ NJIKỌTA: YNd11 ma ọ bụ ndị ọzọ
ỤDỊ: transformer nke e mikpuru mmanụ ma ọ bụ transformer nke substation

    Nkọwa Ngwaahịa

    69kV 4200kVA 5250kVA Transformer Ike nke Usoro Atọ
    Mgbanwe ike 110 kV 115 kV dịka ọkọlọtọ si dị
    1. Nkọwapụta na ihe achọrọ maka GB 6451 maka transformers ike e tinyere mmanụ;
    2. IEC 60076 Power Transformers;
    3. AS NZS 60076 Power Transformers;
    4.CSAC88-16 Transformers Ike;
    5. ANSI/IEEE C57.12.00 IEEE Standard maka ihe achọrọ maka nkesa, ike, na transformers mmiri mmiri;
    6. GOST R 52719 Power Transformers - Nkọwapụta izugbe;
    7. EN60076 Igwe na-agbanwe ike;
    8. Ọrụ Ndị Dị n'Obodo Mgbe A Resịrị Ahịa Na North America, South America na mpaghara ndị ọzọ na-aza mkpa gị n'ime awa iri abụọ na anọ.
    Transformer 115kV
    SF11-20000/115 bụ transformer ike 115 kV 20 MVA, nke JZP Transformer na-enye. Transformer a na-agbaso ụkpụrụ mmepụta siri ike nke ANSI C57 Std. Ọ nwere ikike voltaji dị elu nke 115 kV na ọkwa voltaji dị ala nke 13.8 kV.
    JZP Transformer na-eweta ọtụtụ ahụmịhe na ihe ndekọ a ma ama na ọrụ transformer dị elu n'ime ahịa Amerịka. Ndị otu teknụzụ na ahịa ha na-egosipụta nghọta miri emi nke iwu mpaghara na nrubeisi na ụkpụrụ ANSI, IEEE, na CSA. Transformers HV nke Daelim Transformer achọtala ngwa ndị gara nke ọma na nrụnye dị iche iche na United States, Canada, Mexico, Australia, Ecuador, na mba ndị ọzọ.
    Transformer 115kV
    Atụmatụ Transformer 115 kV 20 MVA
    Voltaji: Transformer a na-arụ ọrụ na 115 kV ma nwee nnukwu ikike nke 20 MVA.
    Ihe Nchekwa Mmanụ: E tinyere ihe nchekwa mmanụ maka ịrụ ọrụ nke ọma na ogologo ndụ.
    Akara otu Vektọ: Transformer ahụ na-eso akara otu vektọ Dyn1.
    Usoro Oyi: Na-eji sistemụ oyi na-agbanwe agbanwe, gụnyere usoro ONAN, ONAF1, na ONAF2. Ọkwa ike dị iche iche dịka usoro ndị a si dị: 12 MVA maka ONAN, 16 MVA maka ONAF1, na 20 MVA siri ike maka ONAF2.
    Ọkwa mkpuchi: A na-etinye ọkwa mkpuchi voltaji dị elu na 550 kV, ebe ọkwa mkpuchi voltaji dị ala bụ 110 kV.
    Ọkwa Okpomọkụ: Emebere transformer a iji jikwaa oke okpomọkụ na-agbagharị agbagharị nke 65℃ na oke okpomọkụ mmanụ nke 55℃.
    Ihe Mgbanwe Mgbata: Akụkụ HV nwere ihe mgbanwe mgbata dị iche iche nke nwere ọnọdụ ise, nke na-enye ohere maka ọkwa nhazi voltaji ise n'ime oke nke ±2×2.5%.
    Bushings: A na-etinye bushings ndị dị elu na ndị dị ala n'elu ha nke ọma.
    Ihe Mgbochi Mkpuchi: Maka nchekwa na nchekwa ka mma, akụkụ voltaji dị elu nwere ihe njide mpịachi atọ.
    Atụmatụ Transformer 115 kV 20 MVA
    Transformer 110kV 115kV
    A na-emepụta ma na-emeziwanye transformers ike 115kV/110kV site na ịmịkọrọ na iji teknụzụ dị elu n'ime obodo na mba ofesi iji melite isi transformer, coil, ahụ, ndu, tankị mmanụ ọkụ, na ihe ndị ọzọ, nke nwere obere mwepụ akụkụ, obere mfu, obere mkpọtụ, obere ọkụ, na ntụkwasị obi dị elu. Arụmọrụ ya dị mma enwetala otuto dị ukwuu site n'aka ndị ọrụ na ndị ọkachamara dị mkpa. Ngwaahịa a nwere njirimara nke nkwụsi ike, akụ na ụba, na nchekwa gburugburu ebe obibi, ọ dịkwa mma maka ụlọ ọrụ ike, ọdụ ụgbọ mmiri, nnukwu ụlọ ọrụ mmepụta ihe na ebe a na-egwupụta ihe, wdg.
    Transformer 110kV 115kV
    Ule na Asambodo
    A na-eme nnwale zuru oke iji hụ na transformer nke 115 kV 20 MVA ruru ụkpụrụ siri ike nke ANSI C57 setịpụrụ. Nnwale ndị a gụnyere:
    Ntụle nke Mkpuchi
    Ntụle nke Oke Voltaji na Otu Vektọ
    Ntụle nke Paramita Ngagharị
    Nnwale Ike-Ugboro nke Isi Iche
    Ntụle nke Ike Bushing na Ihe Mgbasa Dielectric
    Nnwale Ike Mgbatị Ike nke Ọkụ
    Nkwụsị Ike Voltaji na Nnwale Nwepụ Akụkụ
    Ntụle nke Voltaji Impedance na Mfu Ibu
    Ntụle Nnwale Impedance Zero-Short nke Ọkwa Mkpọtụ
    Nnwale Mkpuchi Nrụgide Nnwale Okpomọkụ Mmụba
    Ntụle nke Usoro Nzaghachi Ugboro Ngwa Ngwa
    Ule Nnwale Mgbanwe Ugbu A nke Ule Polarity Ule Nha
    Batrị nnwale a na-eme ka o doo anya na transformer 115 kV na-agbaso ụkpụrụ ANSI C57 ma nwee asambodo zuru oke, na-eme ka a hụ na ọ bụ ntụkwasị obi na arụmọrụ ya.
    Ule na Asambodo
    Nkọwapụta nke Transformer Ike 110kV na 115kV
    110kv Transformer ike okpukpu atọ nke nwere usoro abụọ na-agbanwe ibu
    Ọkwa Njikọta voltaji Enweghị Mfu Ibu Mfu Ibu Enweghị Ibu Ibu Ugbu a Mgbochi mkpụmkpụ
    (kVA) HW LV
    6300 kVA 110kV ±8 6.3kv 10 36 0.8 10.5
    8000 kVA ×1.25% 6.6 kW 12 45 0.8
    10000 kVA   10.5kv 14.2 53 0.74
    12500 kVA 115kV ±8 11kv 16.8 63 0.74
    16000 kVA ×1.25%   20.2 77 0.69
    20000 kVA     24 93 0.69
    25000 kVA     28.4 110 0.64
    31500 kVA     33.8 133 0.64
    40000 kVA     40.4 156 0.58
    50000 kVA     47.8 194 0.58
    63000 kVA     56.8 234 0.52
    110kv Transformer ike nke atọ nke na-agbanwe agbanwe nke ukwuu
    Ọkwa Njikọta voltaji Enweghị Mfu Ibu Mfu Ibu Enweghị Ibu Ibu Ugbu a
    (kVA) HV(kV) MV(kV) LV(kV)
    6300 kVA 110kv±8 35kv 6.3kv 12 47 0.95
    8000 kVA ×1.25% 37kv 6.6 kW 14.4 56 0.95
    10 MVA   38.5kv 10.5kv 17.1 66 0.89
    12.5 MVA 115kv±8   11kv 20.2 78 0.89
    16MVA ×1.25%     24.2 95 0.84
    20MVA       28.6 112 0.84
    25MVA       33.8 133 0.78
    31.5MVA       40.2 157 0.78
    40MVA       48.2 189 0.73
    50MVA       56.9 225 0.73
    63MVA       67.7 270 0.67

    Jụọ ajụjụ ugbu a!

    Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.