Transformer nke nwere otu usoro n'elu—50kVA

Ọkwa Voltaji Mbụ: 13.8 kV/12.47kV/2.4/7.2kV/14.4kV/24.94kV/34.5kV/27.6kV, wdg.
Ọkwa Voltaji nke Abụọ: 120/240V; 240/480V; 347/600Y; 277V; 347V
Oke Mkpọtụ HV: 2280-36225V
ỤDỊ NJIKỌTA: Ii0/Ii6
ỤDỊ: Omenala/CSP
BỤ: 30-150kV
Ụkpụrụ: IEEE/ANSI/CSA/IEC/DOE
Ngwa: Nkesa, Ọrụ

    Nkọwa Ngwaahịa

    Transformer nke JZP Transformer nke nwere ogidi 50 kVA nke nwere asambodo, nwere ndepụta UL ma nwee nkwado site na akụkọ nyocha CESI. Site na oke voltaji dị iche iche nke 2.4-34.5kV, transformer ahụ na-agbaso ụkpụrụ mba ụwa dị iche iche dịka ANSI, IEEE, CSA, IEC, na DOE, na-ahụ na enwere ike ijikọ ya na arụmọrụ zuru ụwa ọnụ. Site na ahụmịhe afọ 20 nke imewe na mbupụ, ndị otu Transformer JZP nwere nkwadebe iji mezuo ihe dị iche iche achọrọ, na-enye ngwọta ahaziri maka transformers pụrụ iche. Site na nkwa siri ike maka afọ ojuju na ịdị mma nke ndị ahịa, Transformer JZP na-enye ngwaahịa a pụrụ ịtụkwasị obi, dị irè, na nchekwa iji gboo mkpa pụrụ iche nke ndị ahịa gburugburu ụwa.
    Transformer nke e ji otu usoro rụọ—37
    Transformer nke e tinyere n'elu osisi 13.8 kV 50 kVA
    JZP Transformer mepụtara D-50-13.8/0.12-0.24kV, transformer nke nwere ogidi 50 kVA, nke e ji nlezianya rụọ, nke na-agbaso ụkpụrụ IEEE C57.12.20. Site na ikike 50kVA, ọ na-arụ ọrụ na 13.8 kV n'akụkụ mbụ ma na-enye 120/240V n'akụkụ nke abụọ. Transformer ahụ nwere bushings voltaji abụọ dị elu, bushings voltaji atọ dị ala, na ihe njide abụọ maka arụmọrụ na nchekwa ka mma.

    JZP Transformer na-ekwe nkwa ịdị mma na ntụkwasị obi kachasị elu na nkeji ọ bụla. Emebere transformers ndị a ka ha mezuo ihe pụrụ iche achọrọ na netwọk nkesa ike Guyanese, na-ahụ na ọkọnọ ike dị irè ma na-agbanwe agbanwe. Site na nkwa siri ike maka afọ ojuju ndị ahịa, JZP Transformer na-enye ngwaahịa dị elu na ọrụ dị mma iji gboo mkpa ụlọ ọrụ ahụ na Guyana.
    13
    14.4 kV 50 kVA Transformer nke otu usoro
    D-50-14.4/0.12-0.24 bụ transformer nke nwere otu usoro 50 kVA. Ọ na-arụ ọrụ na 24940/14400V (voltaji dị elu) na 120/240V (voltaji dị ala) yana otu HV bushing. Transformer ahụ nwere aluminom winding nke na-ezute ụkpụrụ arụmọrụ CSA C2.1 na CSA 802.1. Ọ na-agba ọsọ na 60Hz ma bụrụ nke sistemu oyi ONAN. Transformer ahụ bụ mkpuchi Class A.
    14
    16/27.6kV 50 kVA Transformer nke otu usoro
    D-50-16-27.6kV/347(600Y)V bụ transformer pụrụ iche nke nwere otu usoro 50 kVA, nke e mere maka ngwa pụrụ iche. Ọ na-arụ ọrụ na oke voltaji dị elu nke 16kV na 27.6kV, ọ na-enye obere voltaji na 347(600Y)V.
    JZP Transformer haziri ma rụpụta ya, ọ na-agbaso ụkpụrụ CSA C802.1 na CSA C2.1 siri ike, na-ahụ na arụmọrụ na nchekwa kacha mma. Transformer ahụ na-enye nhọrọ voltaji dị elu abụọ: 16,000V na 27,600V, na-eme ka ọ dị mfe maka ọnọdụ nkesa ike dị iche iche. O nwere bushing voltaji dị elu, bushings obere voltaji abụọ, na switch voltaji abụọ maka nhọrọ voltaji dị mfe.
    Ike pụrụ iche nke transformer a nke nwere voltaji abụọ nke 50kVA nke otu-phase na-egbo mkpa eletriki pụrụ iche na mpaghara ahụ, na-ahụ na ọkọnọ ike a pụrụ ịdabere na ya ma na-emezu ụkpụrụ ụlọ ọrụ kachasị elu.
    1627
    2.4kV 50 kVA Transformer nke otu usoro
    D-50-2.4kV/120(240)V bụ transformer nke ejiri ogidi 50 kVA rụọ, nke nwere voltaji dị elu nke 2.4 kV na voltaji dị ala nke 120V, nke ahaziri maka ndị ahịa Canada. Transformer ọ bụla nwere otu voltaji dị elu na obere voltaji atọ, nke na-eme ka njikọ dịkwuo mma. E ji nlezianya hazie ma mepụta transformers ndị a, ha na-emezu ụkpụrụ CSA siri ike, na-ahụ na arụmọrụ na nchekwa pụrụ iche. Site na ntinye aka na-enweghị mgbagha maka ịdị mma, a haziri transformers ndị a iji gboo mkpa ndị ahịa Canada, na-enye nkesa ike a pụrụ ịdabere na ya ma na-agbaso iwu ụlọ ọrụ niile dị mkpa.