225 kVA 34.5kV Transformer nke nwere usoro atọ
Nkọwa Ngwaahịa
JZP Transformer ji obi ụtọ webata transformer nke nwere usoro pad atọ nke nwere 225 kVA 34.5kV, nke e mere kpọmkwem maka sistemụ nkesa ụlọ ọrụ mmepụta ihe. Emepụtara ya n'ọkwa kachasị elu, ọ na-eme ka ike eletrik sie ike maka ọtụtụ ngwa ụlọ ọrụ mmepụta ihe dị iche iche.
01020304050607
Ihe mgbanwe nke a na-etinye n'elu ya n'usoro atọ
Isi Atụmatụ
Arụmọrụ na Ihe Ọhụrụ
Ngwa Transformer 225 kVA
| Nkọwapụta Teknụzụ nke Transformer 225 kVA 34.5kV | |
| IKE EGOSI | 225 kVA |
| Ọkwa: Voltaji Isi | 34500DELTA |
| Voltaji nke Abụọ | 600GrdY/347 |
| Ugboro ole | 60Hz |
| Òtù VECTOR | Dyn1 |
| Ihe na-agbanwe agbanwe | Aluminom |
| Mfu Ibu | ≤2350W |
| Enweghị Mfu Ibu | ≤650W |
| Voltaji IMPEDANCE | 5.75% |
| UGBO | ≤1,500m |
| Agba | ANSI 70 Isi awọ dị mfe |
| ỊKPOCHI MMIRI | 1,040 L |
| MKPOKỌTA AUTU | 2,300 n'arọ |
| Ngwa ntụgharị 225 kVA 34.5kV | |
| ỤGBỌALA EBILITE | ELSP FUSE |
| Ọnụ Ụzọ E Ji Aka Mee | FUSE BAYONET |
| MGBỌALA NKWỌ AKWỤKWỌ | Pịa Mgbanwe |
| Mkpuchi tankị | NJỤ Ọkwa Mmanụ |
| LV BUSHING (oghere anọ) | VALVỤ MGBASA OKWU |
| NGWAỌRỤ MGBASA OKWU | NJỤ NTỤZI VACUUM |
| Ogwe ọla kọpa HV nke na-eme ka ala dị larịị | BỌCHỊ ỌGBỌ |
| ONYINYE OKPOMỌKỤ | Aka ọnụ ụzọ |
| Ọkụ HV na-arụ ọrụ nke ọma (35kV) | Ọla kọpa nke ala |
| Aka Ogwe Ọla Kọpa nke Na-eme Ala | AHA EMEPỤTA |
| SWICH LOADBREE ỌNỌDỤ ABỤỌ | Ígwè e ji ekpuchi ala |
| 1"'VALV DRAIN NWERE 3/8" SPLER | Windo IR |
| Njikọ Mkpọsa VALV 1" nke Elu | Igbe Ọdụ |
Isi Atụmatụ
Windo IR (Windo Infrared)
E nwere windo IR nke transformer ọ bụla n'ime oghere voltaji dị elu na nke dị ala, nke na-enye ndị ọrụ ohere ime nyocha okpomọkụ infrared na-emegheghị ụzọ. Nhazi a na-eme ka a hụ na a na-enyocha ya nke ọma ma dị irè, na-eme ka a mata ebe ọkụ nwere ike ịpụta ma ọ bụ nsogbu oke okpomọkụ. Site n'ịchọpụta ihe egwu dị ka ibubiga ibu ókè, njikọ na-adịghị mma, ma ọ bụ kọntaktị na-adịghị mma, windo IR na-eme ka ọrụ transformer dịkwuo mma ma na-eme ka nchekwa na nchekwa dịkwuo mma.
Ngwaọrụ Nchedo Dị Elu
Transformer nke nwere ike ibu 225 kVA nwere ọtụtụ usoro nchekwa dị elu iji hụ na nchekwa ọrụ na ndụ ọrụ dị ogologo, gụnyere:
Ihe nlele nrụgide ikuku: Gụnyere kọntaktị mkpu abụọ maka nlekota nrụgide n'oge, na-enye ịdọ aka ná ntị mbụ maka nsogbu ndị nwere ike ime.
Ngwaọrụ Nkwụsị Nrụgide: E tinyere kọntaktị, ọ na-akpali mgbaàmà eletriki mgbe achọpụtara nrụgide na-adịghị mma, na-agwa ndị ọrụ ka ha mee ihe dị mkpa.
Ihe ngosi ọkwa mmanụ: Nwere kọntaktị mkpu abụọ nke na-agwa sistemụ nlekota mgbe ọkwa mmanụ adịghị mma, na-enye ndị ọrụ ohere ịgbanwe ọkwa mmanụ ngwa ngwa ma nọgide na-arụ ọrụ nke ọma.
Ihe Ngosi Okpomọkụ Mmanụ: Gụnyere kọntaktị mkpu abụọ—otu maka akara ịdọ aka ná ntị na otu maka akara njem. Ọ bụrụ na okpomọkụ mmanụ karịrị 70°C, sistemụ ahụ ga-enye ịdọ aka ná ntị; ọ bụrụ na ọ gafere 105°C, transformer ahụ ga-ada ada na akpaghị aka, sistemụ nlekota ahụ ga-ezipụkwa akara iji gosi nsogbu ahụ.
Nhazi na Nleba Anya Mpụga nke Ndị Ọrụ
Nha na Valvụ Drain na Sample nke E tinyere n'èzí: Ndị ọrụ nwere ike ịnwale mmanụ mkpuchi ahụ ma lelee nha ndị ahụ n'ekpugheghị onwe ha na nnukwu voltaji na obere voltaji, na-eme ka nchekwa, arụmọrụ, na nrubeisi dịkwuo mma.
Ihe Nchedo Ngwaọrụ Nrụgide: Ihe nchedo a na-egbochi mmebi mpụga, mkpali mberede, na nnyonye anya site na ihe ndị metụtara gburugburu ebe obibi, na-eme ka ngwaọrụ enyemaka nrụgide na-arụ ọrụ nke ọma ma na-ebelata ihe egwu nke ntapu gas. Ọ na-egbochikwa ihe ndị na-emerụ emerụ ịbanye na transformer, na-eme ka ọ dị ọcha ma kwụsie ike ogologo oge.

Arụmọrụ na Ihe Ọhụrụ
A na-eme transformer 225 kVA nke JZP Transformer ji nlezianya na nchekwa ogologo oge. Site na windo infrared, sistemụ nlekota nwere ọgụgụ isi, na njikwa mpụga nke na-enyere aka iji ya, transformer ahụ abụghị naanị na ọ na-eme ka arụmọrụ rụọ ọrụ ka mma kamakwa ọ na-eme ka nchekwa nke ọrụ mmezi dịkwuo mma. Atụmatụ ndị a na-enyere ndị ọrụ aka ịchọpụta ma dozie nsogbu ndị nwere ike ime ngwa ngwa, na-ebelata oge ọrụ ma na-ahụ na mmepụta na-aga n'ihu.

Ngwa Transformer 225 kVA
Sistemụ nkesa ike ụlọ ọrụ mmepụta ihe
Inye ike azụmaahịa na ebe obibi
Ọdụ mgbanwe ike na ike a na-emegharị emegharị
Ebe nchekwa data na akụrụngwa dị mkpa
Ibu ike dị elu
JZP Transformer—Ịhụ na ike a pụrụ ịdabere na ya maka mkpa gị
JZP Transformer na-agba mbọ inye ndị ahịa ụwa niile ngwọta ike dị elu. Site na teknụzụ dị elu na njikwa mma siri ike, anyị na-ahụ na ọkọnọ ike kwụsiri ike ma bụrụ nke a pụrụ ịtụkwasị obi maka ọrụ ụlọ ọrụ mmepụta ihe na azụmaahịa dị iche iche. Ma ọ bụ nrụnye akụrụngwa, mmezi, ma ọ bụ imewe ahaziri ahazi, anyị na-enye ọrụ ọkachamara na nkwado.

Jụọ ajụjụ ugbu a!
Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.