+86 18068001229 01
Transformers nke nwere usoro atọ nke 500kVA maka ụlọ ọrụ mmepụta ihe
Atụmatụ Nhazi
Isi
Mpempe ígwè silicon a na-akpọ "Cold-rolled": Ọ na-enye ike dị elu site na mkpuchi laminated iji belata mfu nke ikuku.
Nhazi nke akụkụ atọ nke aka ise: Na-ebelata mgbochi usoro efu ma na-egbochi harmonics.
;Windings
Mkpọchi Voltaji Dị Elu: Ejiri akwụkwọ Nomex kpuchie ihe mkpuchi ọla kọpa maka iguzogide oke voltaji.
Mkpọchi Voltaji Dị Ala: Ọdịdị cylindrical dị iche iche maka ike iguzogide obere sekit ka mma.
;Tank na Oyi
Nku radiator corrugated: Ọ na-eme ka convection dị jụụ n'ụzọ ebumpụta ụwa na-enweghị fan mpụga.
Nhazi emechiri emechi nke ọma: Na-egbochi oxidation mmanụ na mmetọ.
;Sistemụ mkpuchi
Mmanụ mineral (ọkọlọtọ) ma ọ bụ mmanụ ester FR3 (nke na-adịghị emebi gburugburu ebe obibi), na-enye mkpuchi, oyi, na mbibi arc.
Ọkwa mwepụ nke akụkụ ≤50pC (IEC 60076 kwekọrọ).




Ngwa
Ogige Mmepụta Ihe
Ọ na-enye ike maka igwe dị arọ, eriri mmepụta (dịka ọmụmaatụ, igwe na-apịpụta ihe, kreen), ma na-akwado ibu arọ dị mkpirikpi.
;Ụlọ Azụmahịa
Na-ekesa ọkụ eletrik maka ọkụ, sistemu HVAC, igwe mbuli elu, na nchekwa n'ụlọ ahịa, họteel, na ọfịs.
Ọrụ Akụrụngwa
Ọdụ ụgbọ okporo ígwè, ebe a na-ahụ maka mmiri mkpofu, na sistemụ ike ọdụ ụgbọelu.
;Mmelite Grid Ime Obodo
Na-anọchi transformers ochie iji melite ntụkwasị obi na arụmọrụ ike.
Uru Ndị Dị Mkpa
Ntụkwasị Obi Dị Elu
Na-agafe ule iguzogide sekit dị mkpụmkpụ nke IEC 60076, na-ahụ na ọ kwụsiri ike n'oge mmejọ grid.
Tankị e mechiri emechi na-agbatị ndụ mmanụ (anaghị edozi ya ruo afọ 10).
;Arụmọrụ Ike
Mfu ibu dị ala na-ebelata ụgwọ ọrụ, na-agbaso ụkpụrụ IEEE C57.12.
;Mgbanwe Gburugburu Ebe Obibi
Ọ na-arụ ọrụ n'oge okpomọkụ dị oke njọ (-40℃ ruo +55℃) na n'ebe dị elu (≤3,000m).
Nhọrọ Smart
Na-akwado njikọta IoT na ihe mmetụta okpomọkụ, ihe nlele ọkwa mmanụ, na mkpu dịpụrụ adịpụ.
Ntụkwasị obi ịdị mma
Ngalaba ọ bụla na-eme nnwale siri ike, gụnyere:
Nnwale mgbochi mkpuchi na ule voltaji mkpali.
Mfu ibu na nha mfu ibu.
Nkwenye dị mkpirikpi nke na-eguzogide sekit.
Asambodo ISO 9001, ISO 14001, na KEMA maka nrubeisi zuru ụwa ọnụ.
Ntuziaka nhọrọ
Ihe achọrọ ibu
Ibu Na-aga n'ihu: Nhọrọ transformers e nyere ọkwa ≥125% nke ibu kachasị atụ anya ya (dịka ọmụmaatụ, 500kVA maka ojiji na-aga n'ihu 400kVA).
Ibu oke obere oge: Ngwa ụlọ ọrụ mmepụta ihe nwere ike ịchọ ikike ibu 150% maka nkeji iri atọ.
;Ọnọdụ Gburugburu Ebe Obibi
Mmiri/Nnu Fesa: Ebe ndị dị n'ụsọ oké osimiri chọrọ ihe mkpuchi mgbochi ire ere.
Ihe achọrọ maka oghere: Hụ na oghere dị n'akụkụ transformer ahụ ruru mita 1.5 maka ndozi.
;Nrubeisi
Ọ dabara na IEC 60076, IEEE C57.12, GB 1094 (China), na ATEX maka gburugburu ebe dị ize ndụ.
;Nhọrọ Mmanụ
Mmanụ Mineral: Ọ dị ọnụ ala maka gburugburu ebe obibi nkịtị.
Mmanụ Ester FR3: Ọ na-eguzogide ọkụ ma dịkwa mma maka ebe ndị nwere mmetụta dị nro (dịka ọmụmaatụ, ebe data).
Ntinye na Mmezi
Ntinye
Jiri ntọala dị larịị nke nwere ike iguzogide ala ≤4Ω.
Njikọ eriri na-akwado eriri 185mm² (ọnụ ụzọ ala ma ọ bụ n'akụkụ).
;Mmezi Oge
N'ime ọnwa atọ: Lelee ọkwa mmanụ, agba, na ntapu.
Kwa afọ: Nwalee iguzogide mkpuchi (2,500V megohmmeter) ma mee nyocha chromatography mmanụ.
Ịchọpụta nsogbu
Okpomọkụ gabigara ókè: Lelee mkpọchi radiator ma ọ bụ ibu ndị na-adịghị mma.
Nweta nke akụkụ: Jiri chromatography mmanụ chọpụta ntụpọ mkpuchi dị n'ime.



Gịnị mere ị ga-eji họrọ anyị
E hiwere JIEZOU POWER, ọkachamara na-emepụta ihe, onye na-emepụta ihe na onye na-etinye ihe ngwọta sistemụ ike gburugburu ụwa, na 1989, na-eburu 200,000 square mita.
JIEZOU POWER, na-ahụ maka ọrụ grid ike, 500KV EPC, 230KV hydroelectric plant, 115KV power substation, wdg.
Ụlọ ọrụ JIEZOU POWER nwere ike imepụta ụdị mmanụ na ụdị akọrọ transformer, transformer ike kachasị 500KV 480MVA, GIS, switchgear, substation, dabere na ọkọlọtọ ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER nwetara asambodo ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, na akụkọ ule ụdị. Ruo afọ 2023, a na-ekesa ụlọ ọrụ na ụlọ ọrụ alaka ụwa niile na United States, Canada, Dubai, Dominican Republic, Philippines, ụlọ ọrụ na ụlọ ọrụ alaka China dị na BengBu City, FengYang City, HaiAn City, TaiZhou City, SuZhou City, ShenYang City, FoShan City.
N'ileba anya n'ọdịnihu, ọhụụ JIEZOU POWER bụ ịbụ onye na-enye ngwọta sistemụ ike kachasị ntụkwasị obi, dozie nsogbu njikwa ike kachasị ngwa ngwa n'ụwa, mee ka mgbanwe ụwa gaa na ike mmeghari ohuru dịkwuo ngwa ngwa. Ka onye ọ bụla wee nwee ike inwe obere carbon na ndụ na-egbuke egbuke. Iji mezuo nke a, anyị ga-eme ike anyị niile iji mee mgbalị.