Leave Your Message

Ngwọta Mgbanwe Ike Omenala ≤2500 kVA

Transformer ike bụ ihe dị oke mkpa na sistemụ eletriki, nke e mere iji nyefee ọkụ eletrik alternating current (AC) nke ọma n'etiti sekit na ọkwa voltaji dị iche iche. Transformers ndị a dị mma maka ịkwalite ma ọ bụ belata voltaji, ha na-ahụ na nkesa ike a pụrụ ịdabere na ya na grid ike, ụlọ ọrụ mmepụta ihe, na ngwa azụmahịa. E mepụtara transformers ike anyị maka ịdịte aka na arụmọrụ, ha na-emezu ụkpụrụ mba ụwa (IEC, IEEE) ebe ha na-ebute nchekwa, arụmọrụ, na ịdịte aka ụzọ.

    Paramita ngwaahịa

    Ụdị

    Ike

    Ọkwa Voltaji

    Jụụ

    Ngwa

    Transformer nkesa

    1,600 kVA

    11 kV / 400 V

    NDỊ Ntorobịa

    Ebe obibi/ụlọ ọrụ mmepụta ihe

    Transformer Ike

    500 MVA

    220 kV / 33 kV

    OFAF

    Ebe nnyefe mpaghara

    Transformer UHVDC

    ±400 kV / 500 MVA

    ±800 kV HVDC

    Mmanụ a manyere

    Grid dị n'etiti kọntinent

    Transformer Rectifier

    20 MVA

    33 kV / 1.8 kV × 6-pulse

    Ụdị akọrọ, nke ikuku jụrụ oyi

    Elektrolysis nke aluminom

    Igwe mgbanwe mmanụ Cooper nke e tinyere n'ime mmiri ugboro ugboro 10001Igwe mgbanwe mmanụ Cooper nke e tinyere n'ime mmiri ugboro ugboro 10002Igwe mgbanwe mmanụ Cooper nke e tinyere n'ime mmiri ugboro ugboro 10003
    Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (1)Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (2)Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (3)Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (4)Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (5)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (1)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (2)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (3)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (4)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (5)
    • Ngwọta Mgbanwe Ike Omenala ≤2500 kVA (6)
    Igwe mgbanwe mmanụ Cooper 01

    nkọwa ngwaahịa

    1. Ike Enyere (MVA/kVA)
    Nkọwa: Ike kachasị elu na-aga n'ihu nke transformer nwere ike inye.
    Oke nkịtị:
    Transformers nkesa: ≤2,500 kVA (dịka ọmụmaatụ, nkesa ọdụ ụlọ ma ọ bụ ụlọ ọrụ mmepụta ihe).
    Transformers Ike: Puku kwuru puku kVA ruo ọtụtụ GVA (dịka ọmụmaatụ, ọdụ nnyefe).
    Transformers Ultra-High Voltage (UHV): Maka njikọ grid ma ọ bụ ojiji ụlọ ọrụ mmepụta ihe, transformers HVDC converter ruru ±800 kV.
    ;2. Ọkwa voltaji
    Voltaji ntinye/mpụta:
    Voltaji dị elu (HV): Dịka ọ na-adịkarị 33 kV ruo ±1,100 kV​ (dịka ọmụmaatụ, netwọk nnyefe).
    Voltaji dị n'etiti (MV): 11 kV nkịtị, 22 kV, 33 kV.
    Voltaji dị ala (LV): Ọ na-abụkarị 400 V ma ọ bụ 6.6 kV (nkesa nye ndị ọrụ njedebe).

    Ngwa Pụrụ Iche:
    ​Ndị na-agbanwe ihe na-agbanwe ihe: Maka igwe/kemịkal, voltaji ruru 30 kV+​.
    ​Ihe Mgbanwe Ụgbọelu: Emebere maka ike ụgbọ okporo ígwè, dịka ọmụmaatụ, 27.5 kV ma ọ bụ 1 × 25 kV.
    ;
    3. Ugboro ole
    Ọkọlọtọ: 50 Hz (China/Europe) ma ọ bụ 60 Hz (North America).
    Ugboro Pụrụ Iche: 400 Hz maka ngwa ụgbọelu/ụgbọ mmiri.
    ;4. Sistemụ Jụụ
    Mmanụ e mikpuru n'ime mmiri:
    ONAN (Mmanụ Ikuku Okike): Ọkụ ikuku sitere n'okike.
    ONAF (Mmanụ sitere n'okike nke ikuku na-amanye): Ikuku oyi nke a na-amanye iji mee ka ọ dị mma.
    Ụdị Akọrọ: A na-eme ka ikuku jụọ oyi, ọ dị mma maka ebe dị n'ime ụlọ/ebe ọkụ na-anaghị emetụ aka (dịka ọmụmaatụ, ebe nchekwa data).
    ​Igwe mkpuchi gas (GIS): SF6 gas mkpuchi, imewe dị obere maka obere ọdụ ndị nwere njupụta dị elu.
    ;5. Ụdị mkpuchi
    Mmanụ e tinyere n'ime mmiri: Mmanụ mineral ma ọ bụ mmanụ ester (ọ dịghị mma maka gburugburu ebe obibi).
    Ụdị Akọrọ: Ihe nkedo resin epoxy ma ọ bụ mkpuchi akwụkwọ Nomex (ọkụ/mgbawa anaghị agbawa).
    Igwe anaghị agbaze: SF6 ma ọ bụ gas agwakọtara (ebe ndị nwere obere voltaji dị elu).
    ;6. Ịrụ ọrụ nke ọma
    Ụkpụrụ nkịtị:
    Transformers nkesa: ≥98% (enweghị ibu na mfu ibu dị ala).
    Transformers Ike: ≥99% (ụdị voltaji dị elu na-arụpụta arụmọrụ ka elu).
    Ụkpụrụ: Soro IEC 61620 ma ọ bụ IEEE C57.12 (dịka ọmụmaatụ, ihe EU chọrọ maka nhazi Eco).
    ;7. Njikọ otu
    Ọdịiche nke Oge: Achọpụtara ya dị ka Dyn11, Yd11, nke na-egosi mmekọrịta dị n'etiti windings iji jikwaa harmonics na short-circuit currents.
    ;8. Voltaji Impedance
    Nkọwa: Mbelata voltaji pasentị n'oge nnwale sekit dị mkpụmkpụ, na-egosipụta ikike iguzogide sekit dị mkpụmkpụ.
    Ụkpụrụ nkịtị: 4–10% (transformers ike), ≤4% (transformers nkesa).
    ;9. Mmụba okpomọkụ
    Oke: Transformers ndị e tinyere mmanụ na-eme ka okpomọkụ ha dịkwuo elu karịa ≤55 K (mmanụ dị n'elu na gburugburu 40°C).
    Mgbanwe Gburugburu Ebe Obibi: Mpaghara ọzara chọrọ ka e mee ka ha dị elu.
    ;10. Ọkwa Nchedo
    Koodu IP:
    IP23: Ihe mkpuchi a na-echebe site na uzuzu, mmiri na-eguzogide.
    IP66/IP68: Emechiri nke ọma megide uzuzu/mmiri (ngwa mmiri/oke osimiri).
    Gburugburu Pụrụ Iche: Nnu fesa na-eguzogide nchara maka ojiji n'ụsọ oké osimiri/okpuru mmiri.
    11. Ụdị Pụrụ Iche
    Transformers Rectifier: Nhazi ọtụtụ pulse (dịka ọmụmaatụ, 12/24-pulse) iji belata harmonics.
    Transformers Na-agbanwe Mgbapụ: Ihe mgbanwe mgbapụ n'elu ibu (OLTC) maka nhazi voltaji.
    Transformers Pụrụ Iche:
    ​Ihe na-agbanwe ọkụ eletrik: Emebere ya maka ibu oke ibu n'oge dị mkpirikpi (dịka ọmụmaatụ, ịgbaze ígwè).
    Mgbanwe Zigzag: Sistemụ ntọala na-anọpụ iche maka mgbochi harmonic.

    Ngwa    Ọkwa Voluji   Ike Ụdị   Ngwa  ...

    Transformer nkesa 1,600 kVA 11 kV / 400 V ONAN Ebe obibi/ụlọ ọrụ mmepụta ihe
    Transformer Ike 500 MVA 220 kV / 33 kV OFAF Ebe nnyefe mpaghara
    Igwe mgbanwe UHVDC ±400 kV / 500 MVA ±800 kV HVDC Mmanụ mmanye dị n'etiti kọntinent
    Transformer Rectifier 20 MVA 33 kV / 1.8 kV × 6-pulse Ụdị akọrọ, nke a na-eme ka ọ dị jụụ site na ikuku.
    Igwe mgbanwe mmanụ Cooper 02Igwe mgbanwe mmanụ Cooper 03Transformer nke e tinyere mmanụ Cooper 04Igwe mgbanwe mmanụ Cooper 05

    Gịnị mere ị ga-eji họrọ anyị

    E hiwere JIEZOU POWER, ọkachamara na-emepụta ihe, onye na-emepụta ihe na onye na-etinye ihe ngwọta sistemụ ike gburugburu ụwa, na 1989, na-eburu 200,000 square mita.
    JIEZOU POWER, na-ahụ maka ọrụ grid ike, 500KV EPC, 230KV hydroelectric plant, 115KV power substation, wdg.
    Ụlọ ọrụ JIEZOU POWER nwere ike imepụta ụdị mmanụ na ụdị akọrọ transformer, transformer ike kachasị 500KV 480MVA, GIS, switchgear, substation, dabere na ọkọlọtọ ANSI/IEEE/DOE2016/CSA/IEC60076.
    JIEZOU POWER nwetara asambodo ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, na akụkọ ule ụdị. Ruo afọ 2023, a na-ekesa ụlọ ọrụ na ụlọ ọrụ alaka ụwa niile na United States, Canada, Dubai, Dominican Republic, Philippines, ụlọ ọrụ na ụlọ ọrụ alaka China dị na BengBu City, FengYang City, HaiAn City, TaiZhou City, SuZhou City, ShenYang City, FoShan City.
    N'ileba anya n'ọdịnihu, ọhụụ JIEZOU POWER bụ ịbụ onye na-enye ngwọta sistemụ ike kachasị ntụkwasị obi, dozie nsogbu njikwa ike kachasị ngwa ngwa n'ụwa, mee ka mgbanwe ụwa gaa na ike mmeghari ohuru dịkwuo ngwa ngwa. Ka onye ọ bụla wee nwee ike inwe obere carbon na ndụ na-egbuke egbuke. Iji mezuo nke a, anyị ga-eme ike anyị niile iji mee mgbalị.
    Igwe mgbanwe mmanụ Cooper 06Igwe mgbanwe mmanụ Cooper 07Igwe mgbanwe mmanụ Cooper 08Igwe mgbanwe mmanụ Cooper 09

    Jụọ ajụjụ ugbu a!

    Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.

    Leave Your Message