+86 18068001229 01
Transformers Akọrọ-Ụdị Dị Elu Arụmọrụ
Atụmatụ na Uru Ndị Dị Mkpa
Nhazi na-anaghị agba ọkụ na gburugburu ebe obibi
Enweghị mmanụ ọkụ, transformers ndị a kpọrọ nkụ na-agbaso ụkpụrụ nchekwa ọkụ siri ike (IEC 61558) ma dị mma maka ụlọ ọgwụ, ebe data, na ụlọ obibi. Ihe ndị a na-emegharị emegharị na enweghị mmiri mmanụ na-eme ka e nwee ike ịgbaso gburugburu ebe obibi.
nkeArụmọrụ dị elu na nchekwa ike
Ihe ndị dị elu (amorphous alloy ma ọ bụ silicon steel) na imewe winding kachasị mma na-ebelata mfu ike ruo 30%, na-enweta ọkwa arụmọrụ ≥98% (IEC 61378 kwadoro). Dabara adaba maka ọrụ na-aga n'ihu na obere mmepụta okpomọkụ.
nkeObere mmezi na ogologo oge
Sistemụ mkpuchi siri ike na-eguzogide mmiri mmiri, uzuzu, na ihe ndị na-emerụ emerụ, na-ebelata mkpa mmezi. Ihe owuwu siri ike na-eguzogide ọnọdụ siri ike, na-agbatị ndụ ọrụ na gburugburu ụlọ ọrụ mmepụta ihe ma ọ bụ n'ụsọ oké osimiri.
nkeObere na Nchekwa Oghere
Nhazi modular na obere akara ụkwụ na-eme ka ntinye dị mfe n'ọdụ ụgbọ ala obodo ukwu, ụlọ azụmahịa, ma ọ bụ ebe ike mmeghari ohuru. A na-enweta ya na voltaji site na 380V ruo 36kV yana ikike ruo 5 MVA.
nkeNlekota na Nchekwa Smart
Ihe mmetụta IoT nhọrọ na-enyocha okpomọkụ, voltaji, na ibu n'oge dị adị, na-eme ka mmezi amụma dị. Sistemụ nchekwa arụnyere n'ime ya (dịka ọmụmaatụ, relays okpomọkụ, mkpu Buchholz) na-egbochi mmejọ ma hụ na arụ ọrụ dị mma.




Ngwa
Akụrụngwa Obodo: Nkesa ike dị mma n'ebe ndị mmadụ na-enwe oke njupụta, ụlọ ahịa, na sistemụ ụgbọ oloko.
Ojiji ụlọ ọrụ: Inye ọkụ na-adịgide adịgide maka ụlọ ọrụ mmepụta ihe, ọrụ igwu ala, na ụlọ ọrụ kemịkalụ.
nkeIke Mmegharị: Njikọta na ugbo anyanwụ/ikuku maka njikọ grid dị irè.
nkeỤlọ Azụmahịa: Sistemụ HVAC, igwe mbuli elu, na netwọk ọkụ.
Nkọwapụta Nkà na ụzụ
Oke voltaji: 380V ruo 36kV (voltaji dị n'etiti).
nkeIke: 50 kVA ruo 5,000 kVA.
nkeỤdị oyi: Ikuku Eke (AN) ma ọ bụ Ikuku Ike (AF).
nkeKlas mkpuchi: H-klas (180°C) maka ike dị elu nke iguzogide okpomọkụ.
nkeUgboro ole: 50Hz/60Hz.
Ntụkwasị obi ịdị mma
Nnwale siri ike gụnyere voltaji mkpali, mfu ibu, na ihe ngosi mmụba okpomọkụ.
Asambodo nke IEC, IEEE, ISO 9001 (ịdị mma), na ISO 14001 (gburugburu ebe obibi) kwadoro.
Gịnị Mere Ị Ji Họrọ Anyị?
Afọ 30+ nke Ọkachamara: Atụmatụ egosipụtara maka oke okpomọkụ, iru mmiri, na mpaghara ala ọma jijiji.
nkeNkwado zuru ụwa ọnụ: Ndị otu injinia mpaghara na enyemaka teknụzụ awa iri abụọ na anọ n'ụbọchị asaa.
nkeNgwọta Dị Irè: Nhazi ndị a na-agbanwe agbanwe nwere nhọrọ ego na-agbanwe agbanwe.
Ngwọta Omenala
Ụdị ndị na-eguzogide ọkụ na ndị na-egbochi mgbawa: Maka ebe mmanụ/gas ma ọ bụ ebe dị ize ndụ.
nkeNhazi Ndị Dị Mma Maka Gburugburu Ebe Obibi: Mkpọtụ dị ala (
nkeSistemụ Ngwakọta: Ejikọtara ya na nchekwa ike maka ngwa grid smart.



Uru ngwaahịa
1. Ihe ndị bụ isi na imewe windo
Ihe Ndị Dị Mkpa
Akụkụ Amorphous Alloy:
Mfu ígwè dị oke ala (70-80% dị ala karịa ígwè silicon ọdịnala), na-ebelata mmefu ike na ọnụ ahịa ọrụ.
Oke ikike na-adịgide adịgide na ihe na-adịghị mma nke magnetostriction na-ebelata mkpọtụ na mkpọtụ, nke dị mma maka ebe obibi na ebe azụmaahịa.
Ígwè silicon nke a na-akpọ "Cold-Roriented Grain-Controled" (CRGO):
Ihe e ji lamination nke e ji laser bee ma ọ bụ nke e ji steepụ mee na-ebelata mfu nke ọkụ eletrik, na-enweta ọkwa arụmọrụ ruo 98% (ọkọlọtọ IEC 60076).
Nhazi ọka kachasị mma na-eme ka njupụta mgbanwe magnetik dịkwuo mma maka ngwa voltaji dị elu (ruo 33kV).
Nhazi Winding
Mkpọchi foil na ntụnye resin:
Mkpọchi foil ọla kọpa ma ọ bụ aluminom na-ebelata mmiri na-agbapụta na ike sekit dị mkpụmkpụ. Mkpọchi resin epoxy na-eme ka ike mekaniki na ike okpomọkụ dịkwuo mma.
Ihu akwụkwọ ndị dị n'etiti na-ebelata nrụgide voltaji n'etiti ntụgharị, na-eme ka iguzogide obere sekit dịkwuo mma (ruo 50 kA asymmetrical failures).
Njikọ Waya Litz nke Ejiri Layi:
Waya Litz nke nwere ọtụtụ eriri na-ebelata mmetụta akpụkpọ ahụ na nso nso, na-ebelata iguzogide AC na ngwa ugboro ugboro (dịka ọmụmaatụ, ndị na-agbanwe HVDC).
Ntinye nrụgide vacuum-pressure (VPI):
A na-etinye resin epoxy ma ọ bụ polyester dị elu n'ime kọlụm ndị ahụ, na-eme ka mmiri ghara iguzogide ya ma nwee ike dielectric ruo 200 kV BIL.
;2. Sistemụ mkpuchi
Ngwakọta nke resin epoxy:
Mkpuchi siri ike nke nwere resin epoxy Class H na-enye ike iguzogide ọkụ (nke UL94 V-0 kwadoro) ma na-eguzogide ike ịgbagharị okpomọkụ (−40°C ruo +155°C).
Oke ike iguzogide mwepụ nke akụkụ, dị mma maka gburugburu ebe ruru unyi ma ọ bụ mmiri mmiri.
Ihe mejupụtara akwụkwọ Nomex:
Mkpuchi nke dabere na eriri Aramid na-enye ike dị elu maka okpomọkụ (ruo 220°C) na ike dielectric, yana ihe ndị na-egbochi ire ọkụ.
Ihe mkpuchi emelitere na Nano:
Ngwakọta epoxy jupụtara na silica na-eme ka ndụ mwepụta akụkụ dị mma site na 40%, na-agbatị ndụ ọrụ n'ọnọdụ siri ike.
;3. Njikwa Okpomọkụ
Ikuku-Nkịtị oyi (AN):
Ọ na-eme ka oyi dị jụụ site na radiator ndị a kpụchara akpụcha ma ọ bụ sink okpomọkụ maka ịrụ ọrụ na-aga n'ihu na ibu dị elu (dịka ọmụmaatụ, nkeji 500kVA–1.5MVA).
Ikuku oyi nke ejiri ike mee (AF):
Ndị na-afụ ọkụ na-achịkwa okpomọkụ na-eme ka okpomọkụ na-agbaze ngwa ngwa, na-eme ka ikike ibufe ihe karịrị 120–150% maka ọnọdụ mberede.
Nlekota Okpomọkụ Smart:
Ihe mmetụta okpomọkụ agbakwunyere na sistemụ IoT na-akpali mkpu ma ọ bụ mgbanwe oyi iji gbochie oke okpomọkụ na mmebi mkpuchi.
;4. Nhazi na Nchedo Nhazi
Nhazi Modular na Kọmpat
Ihe mkpuchi Hermetic:
Ihe mkpuchi IP66/IP67 nwere gaskets EPDM na-echebe megide uzuzu, mmiri, na mwakpo oke, nke dị mma maka gburugburu ebe obibi dị n'èzí ma ọ bụ ụlọ ọrụ mmepụta ihe.
Ihe mkpuchi mgbochi corrosion:
Ihe mkpuchi ígwè ma ọ bụ aluminom nke e ji ihe mkpuchi polyurethane/ntụ ntụ mee na-eguzogide mmebi UV na ikpughe nnu n'ụsọ oké osimiri.
Ihe ndị na-eguzogide ọkụ:
Mkpuchi na-anaghị ere ọkụ na sistemụ resin nke na-emenyụ onwe ya na-emezu ụkpụrụ nchekwa ọkụ nke IEC 60335.
Atụmatụ Nchekwa
Sistemụ Enyemaka Nrụgide:
Oghere ndị na-ebelata nrụgide akpaka na-egbochi mmebi mgbawa n'oge nsogbu dị n'ime.
Nchedo Mkpuchi:
Ihe njide ígwè oxide (MOA) jikọtara ọnụ na-egbochi ihe ndị na-agbanwe agbanwe nke àmụ̀mà na-akpata (≥2.5 kA pulses).
Mgbochi Ịkụ Ala na Mwụfu Mmiri:
Sistemụ ntọala siri ike na atụmatụ mechiri emechi na-ewepụ ihe egwu nke ntapu mmanụ, na-eme ka ọ ghara inwe mmetọ gburugburu ebe obibi.
;5. Ọrụ Dị Elu
Sistemụ Nlekota Ọnọdụ (CMS):
Ihe mmetụta ndị e tinyere n'ime ya na-esochi okpomọkụ na-agbagharị agbagharị, mwepụ akụkụ, na ọkwa ibu, na-eme ka mmezi amụma dị irè site na nyiwe SCADA ma ọ bụ IoT.
Njikọta Grid Smart:
Nkwukọrịta IoT na-akwado nlekota anya n'ebe dị anya, nhazi ibu, na nzaghachi grid na-agwọ onwe ya.
Mmepụta Ihe Ọhụrụ Maka Gburugburu Ebe Obibi:
Resin mkpuchi ihe ndị dị na bio na ihe ndị e ji eme polima a na-emegharị emegharị na-adaba na ebumnuche nkwado (dịka ọmụmaatụ, nrubeisi RoHS na REACH).
Ngwa Ndị Dị Mkpa na Usoro Ọdịnihu
Nkesa Obodo na Azụmaahịa:
Ebe nchekwa ike, ebe nchekwa data, na ebe a na-eji chaja EV arụ ọrụ nke nwere njupụta dị elu (500kVA–2 MVA).
Ike Mmepụta na Ike Mmegharị:
Ọ dị mma maka ebe ndị na-arụ ọrụ ugbo anyanwụ/ikuku, ebe a na-egwupụta ihe, na ebe ndị dị ize ndụ (Mpaghara 2/22).
Ọganihu n'ọdịnihu:
Ndị na-agbanwe agbanwe nke steeti siri ike (SSTs): Mee ka mgbanwe DC-DC na mgbanwe grid dị mfe maka sistemụ ike na-adịghị agbanwe agbanwe.
Nanocomposites Na-eme Ka Oyi Jụụ Onwe Ya: Ihe ndị dị elu na-ewepụ okpomọkụ n'onwe ha n'ọnọdụ nsogbu.
Nchịkọta
Transformers nke ụdị akọrọ na-eme nke ọma site na isi amorphous dị ala, iguzogide ihe mkpuchi siri ike, na njikwa okpomọkụ mara mma. Nchekwa ọkụ ha, ọrụ ha na-enweghị mmezi, na imewe ndị na-adịghị emebi gburugburu ebe obibi na-eme ka ha dị mkpa maka grid obodo na ụlọ ọrụ mmepụta ihe nke oge a, ebe ihe ọhụrụ dị ka teknụzụ steeti siri ike na njikọta IoT na-akwalite ọgụgụ isi grid na nkwado.



Jụọ ajụjụ ugbu a!