Igwe Mgbanwe Mmanụ 220kVA Dị Elu Maka Ngwa Ndị Dị Oké Mkpa
Atụmatụ Nhazi
Isi
Mpempe ígwè silikọn a na-akpọchi akpọchi nke nwere mkpuchi oyi na-adịgide adịgide nke nwere ike ime ka ihe ghara ịpụ apụ iji belata mfu nke ikuku ọkụ.
Nhazi nke akụkụ atọ nke ụkwụ ise iji belata mgbochi nke usoro efu ma gbochie harmonics.
;Windings
Mkpọchi Voltaji Dị Elu: Ejiri akwụkwọ Nomex kpuchie ihe mkpuchi dị n'etiti ihe mkpuchi ahụ.
Mkpọchi Voltaji Dị Ala: Ọdịdị cylindrical dị iche iche maka ike iguzogide obere sekit ka mma.
;Tank na Oyi
Nhazi ONAN nwere mgbasa mmanụ sitere n'okike na enweghị fan mpụga, nke dị mma maka nrụnye n'èzí.
A na-etinye nku radiator corrugated n'ime tankị ahụ maka iwepụ okpomọkụ nke ọma.
;Sistemụ mkpuchi
Mmanụ ala (ma ọ bụ mmanụ ester nke na-adịghị emebi gburugburu ebe obibi) na-enye mkpuchi, oyi, na mbibi arc.
Ọkwa mwepụ nke akụkụ ≤50pC (IEC 60076 kwekọrọ).




Ngwa
Nkesa Ike Ụlọ Ọrụ
Nkesa voltaji dị n'etiti (10kV ruo 0.4kV) n'ụlọ ọrụ mmepụta ihe, ebe a na-egwupụta ihe, na ụlọ ọrụ ígwè.
Na-akwado ibu arọ nwa oge (dịka ọmụmaatụ, ọkụ eletrik, mmalite moto).
;Ụlọ azụmaahịa
Nkesa ọkụ eletrik maka ụlọ ahịa, ụlọ elu ọfịs, na họtel.
;Akụrụngwa
Ọdụ ụgbọ okporo ígwè, ọdụ ụgbọelu, na ụlọ ọrụ na-ahụ maka mmiri mkpofu.
;Ebe Ndị Dị Anya
Ọ na-arụ ọrụ nke ọma n'ebe iru mmiri dị elu, uzuzu uzuzu, ma ọ bụ ebe okpomọkụ na-agbanwe agbanwe.
Uru Ndị Dị Mkpa
Ntụkwasị Obi Dị Elu
Tankị mechiri emechi nke ọma na-egbochi oxidation mmanụ na mmetọ.
Ike siri ike nke iguzogide obere sekit (dabere na GB/T 1094.5).
;Mmezi dị ala
Nhazi enweghị mmezi yana nleba anya n'ọkwa mmanụ na okpomọkụ n'oge.
;Dị irè
Obere itinye ego mbụ na obere mfu ike ọrụ.
;Nhọrọ Ndị Dị Mma Maka Eco-Friendly
A na-enweta ya na mmanụ ester nke nwere ike imebi emebi (dịka ọmụmaatụ, FR3) maka nnabata RoHS.
Ntuziaka nhọrọ
Ngalaba ọ bụla na-eme nnwale siri ike, gụnyere:
Nnwale mgbochi mkpuchi na ule voltaji mkpali.
Mfu ibu na nha mfu ibu.
Nkwenye dị mkpirikpi nke na-eguzogide sekit.
Asambodo ISO 9001, ISO 14001, na KEMA maka nrubeisi zuru ụwa ọnụ.
Ntuziaka nhọrọ
Njirimara Ibu
Gosipụta ụdị ibu (na-agbanwe agbanwe ma na-agbanwe agbanwe).
Nyochaa ihe achọrọ maka ibu oke ibu nwa oge (dịka ọmụmaatụ, ọkụ eletriki arc).
;Ọnọdụ Gburugburu Ebe Obibi
Elu ≤ mita 1,000 (a chọrọ iwepụ ihe n'elu nke a).
Okpomọkụ gburugburu ebe obibi: -25℃ ruo +45℃ (mkpọnwụ ka mma maka mpaghara okpomọkụ).
;Nrubeisi
Ọ na-emezu GB 1094 (China), IEC 60076 (mba ụwa), yana asambodo ndị metụtara ụlọ ọrụ (dịka ọmụmaatụ, ATEX maka ikuku mgbawa).
Ntinye na Mmezi
Ihe achọrọ maka nrụnye
Ntọala dị larịị nwere oghere ≥1m n'akụkụ niile maka mwepụ okpomọkụ.
Nguzogide ala ≤4Ω; nhazi nchekwa àmụ̀mà dị iche.
;Mmezi Oge
Lelee ọkwa mmanụ, agba ya, na mmiri na-agbapụta kwa ọnwa isii.
Nwalee iguzogide mkpuchi kwa afọ site na iji megohmmeter 2,500V.
;Ịchọpụta nsogbu
Okpomọkụ gabigara ókè: Lelee mkpọchi radiator ma ọ bụ ibu ndị na-adịghị mma.
Nyocha Chromatography Mmanụ: Chọpụta ihe ịrịba ama mbụ nke mwepụta n'ime ma ọ bụ mmebi mkpuchi.



Gịnị mere ị ga-eji họrọ anyị
E hiwere JIEZOU POWER, ọkachamara na-emepụta ihe, onye na-emepụta ihe na onye na-etinye ihe ngwọta sistemụ ike gburugburu ụwa, na 1989, na-eburu 200,000 square mita.
JIEZOU POWER, na-ahụ maka ọrụ grid ike, 500KV EPC, 230KV hydroelectric plant, 115KV power substation, wdg.
Ụlọ ọrụ JIEZOU POWER nwere ike imepụta ụdị mmanụ na ụdị akọrọ transformer, transformer ike kachasị 500KV 480MVA, GIS, switchgear, substation, dabere na ọkọlọtọ ANSI/IEEE/DOE2016/CSA/IEC60076.
JIEZOU POWER nwetara asambodo ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, na akụkọ ule ụdị. Ruo afọ 2023, a na-ekesa ụlọ ọrụ na ụlọ ọrụ alaka ụwa niile na United States, Canada, Dubai, Dominican Republic, Philippines, ụlọ ọrụ na ụlọ ọrụ alaka China dị na BengBu City, FengYang City, HaiAn City, TaiZhou City, SuZhou City, ShenYang City, FoShan City.
N'ileba anya n'ọdịnihu, ọhụụ JIEZOU POWER bụ ịbụ onye na-enye ngwọta sistemụ ike kachasị ntụkwasị obi, dozie nsogbu njikwa ike kachasị ngwa ngwa n'ụwa, mee ka mgbanwe ụwa gaa na ike mmeghari ohuru dịkwuo ngwa ngwa. Ka onye ọ bụla wee nwee ike inwe obere carbon na ndụ na-egbuke egbuke. Iji mezuo nke a, anyị ga-eme ike anyị niile iji mee mgbalị.



Jụọ ajụjụ ugbu a!
Maka ajụjụ gbasara ngwaahịa anyị ma ọ bụ onye na-ere ahịa, biko hapụ email gị nye anyị, anyị ga-akpọtụrụ gị n'ime awa 24.