+86 18068001229 Kedu ihe bụ ihe na-eme ka ọkụ si n'ala?
ATransformer Ọkụ Ngwuputabụ ụdị transformer pụrụ iche nke e mere kpọmkwem iji nye ike na sistemụ ọkụ n'ime ebe a na-egwupụta ihe (gụnyere kol na ebe a na-egwupụta ihe na-abụghị kol). Ọrụ ya bụ isi bụ inyenchekwa, a pụrụ ịtụkwasị obi, ma kwụsie ikeobere voltaji iji rụọ ọrụ na ngwaọrụ ọkụ dị n'okpuru ala.
Isi Njirimara na Ebumnuche Nhazi:
Mgbanwe voltaji:Ọ na-agbanwekarị voltaji dị elu nke grid ike nke ebe a na-egwupụta ihe (dịka ọmụmaatụ, 660V, 1140V) ka ọ bụrụ aVoltaji dị ala nke nchekwa (SELV)sistemụ ọkụ chọrọ, nke a na-ejikarị eme ihe127VA na-ewere ọkwa voltaji a dị ka ihe dị nchebe n'ebe mmiri dị mmiri ma na-eduzi ya, nke na-ebelata nke ukwuu ihe egwu nke ujo eletrik.
Mwepụ Nchekwa:Ọ bụTransformer nkewapụA na-ekewapụ eriri nke abụọ ya (akụkụ mmepụta) site na eletriki site na ụwa na eriri mbụ (akụkụ ntinye). Nke a pụtara na ọ bụrụgodị na onye na-egwuputa ihe emetụ otu ahịrị nke mmepụta 127V na ala n'otu oge, a gaghị emepụta sekit mechiri emechi, si otú a na-egbochi ujo eletrik.
Ibu raara onwe ya nye:Ebumnuche ya bụ inye ọkụ ọkụ (dịka ọmụmaatụ, ọkụ ọkụ incandescent, ọkụ LED). Njirimara ibu ya na-adịgide adịgide, ikike ya na-adịkarị obere (site na kVA ole na ole ruo ọtụtụ iri kVA).
Nchedo Isi:Ọ bụ ezie na o nwekwara ụfọdụ ihe nchebe n'ihe ndị e ji arụ ọrụ n'ime ala (dịka iguzogide mmiri, iguzogide ujo), isi ihe ọ na-elekwasị anya bụ inye ebe ike dị nchebe, ọ bụghị naanị ijikwa oke gas na-agbawa agbawa.
N'ikwu ya n'ụzọ dị mfe, ihe na-eme ka ọkụ si n'ala bụ "obi nchekwa" nke ihe na-eme ka ọkụ si n'ala ahụ pụta; ọrụ ya bụ isi bụ "igbochi ihe mberede."
Kedu ihe bụ Transformer Mining nke Na-egbochi Mgbawa?
AnTransformer nke Na-egosi Mgbawa nke Ngwuputabụ echiche sara mbara nke na-ezo aka na transformers niile e mere iji gbochie ịgba ọkụ nke ngwakọta gas na-agbawa agbawa gburugburu ma enwere ike iji ya na gburugburu ebe ihe egwu na-agbawa agbawa. Ọ bụghị naanị isi iyi ike maka sistemụ ọkụ kama ọ bụ akụkụ bụ isi nke sistemụ ike dị n'okpuru ala dum.
Isi Njirimara na Ebumnuche Nhazi:
Ọrụ owuwu nke na-egosi mgbawa:Nke a bụ isi ihe dị na ya. Ọ na-eji ihe mkpuchi pụrụ iche nke na-egbochi mgbawa ("Ụdị Nchedo"), dịka ọmụmaatụ:
Mkpuchi na-anaghị ere ọkụ ('Ex d'):Ihe mkpuchi ahụ nwere ike iguzogide mgbawa dị n'ime ma gbochie ire ọkụ dị n'ime ịgbasa gaa na ikuku dị n'èzí, si otú a ghara ịgba ọkụ gas gbara ya gburugburu.
Nchekwa Karịrị Elu ('Ex e'):A na-etinye ihe ndị ọzọ n'ọrụ transformer na terminal ndị na-anaghị emepụta arcs, sparks, ma ọ bụ ihe ndị dị ize ndụ n'oge ọrụ nkịtị, nke na-eme ka nchekwa dịkwuo mma.
Ike Dị Elu:Ike ya na-abụkarị nnukwu (site na iri kVA ruo ọtụtụ puku kVA), nke a na-eji enye ike dị iche iche n'okpuru ala, dịka ọmụmaatụihe e ji akpụcha ákwà, ihe e ji ekpuchi ụzọ, eriri ihe e ji ebufe ihe, pọmpụ mmiri, na fan enyemaka.
Voltaji mmepụta dị iche iche:Voltaji mmepụta ya na-agbanwe dịka mkpa akụrụngwa ejikọtara si dị, nke nwere ike ịbụ ọkwa voltaji dị n'etiti dịka 660V, 1140V, 3300V, wdg. O nwekwara ike ịgụnye winding 127V maka ọkụ, mana nke a abụghị ọrụ ya bụ isi.
Nchedo zuru oke:E wezụga na ọ na-eguzogide mgbawa, ọ ghaghịkwa inwe usoro ígwè siri ike, ezigbo iguzogide mmiri, iguzogide nchara, na iguzogide ujo iji kwekọọ na gburugburu ebe ọrụ dị n'okpuru ala siri ike.
N'ikwu ya n'ụzọ dị mfe, ihe na-eme ka e nwee ike ịgbawa ihe mgbawa bụ "isi ike na-anaghị agbawa ihe mgbawa" nke sistemụ ike nke ebe a na-egwupụta ihe; ọrụ ya bụ isi bụ "igbochi mgbawa" na inye ike maka ngwa dị iche iche.
Isi Ihe Dị Iche n'etiti Ha Abụọ