Okwu Mmalite

A na-akpọkarị mmanụ transformer "ọbara" nke transformer. Ọ na-ekpuchi ihe mkpuchi, na-eme ka ọ dị jụụ, na-echebe, ma na-achọpụta ọrịa. Ruo ihe karịrị otu narị afọ, mmanụ mineral sitere na mmanụ ala abụrụla nhọrọ a na-ahọrọkarị. Mana mmụba nke nchegbu gburugburu ebe obibi na ihe achọrọ maka nchekwa ọkụ emeela ka e nwee ihe ndị ọzọ - nke kachasị mkpa bụ mmanụ ester eke sitere na ihe ọkụkụ.

Isiokwu a na-enyocha mgbanwe nke mmiri mkpuchi transformer ma kọwaa ihe ọdịiche ndị a pụtara maka ndị ọkachamara n'ịzụta ihe.

Akụkụ nke Mbụ: Ọrụ dị iche iche nke mmanụ transformer na-arụ.

Mkpuchi.Ọrụ bụ isi bụ inye mkpuchi eletriki n'etiti ihe ndị dị ndụ. Ike dielectric ya dị elu na-egbochi sekit dị mkpụmkpụ na mmebi eletriki.

Ịjụ oyi.Mmanụ na-agafe site na windings na core, na-ebuga okpomọkụ na radiators ebe ọ na-agbasa n'ikuku.

Ịgbachi Arc.Ọ bụrụ na nsogbu dị n'ime ahụ emee, mmanụ na-enyere aka imenyụ ihe ndị na-esi na ya apụta, na-egbochi obere nsogbu ka ha ghara ịka njọ.

Nchedo.Mmanụ na-eme ihe mgbochi n'etiti ihe mejupụtara ígwè na ikuku oxygen, na-egbochi ire ere.

Nchọpụta ọrịa.Mmanụ na-arụ ọrụ dị ka ihe na-ebu ozi. Nyocha gas agbazere agbaze na-atụle gas ndị ụdị njehie dị iche iche mepụtara, na-enye ịdọ aka ná ntị mbụ maka nsogbu ndị na-apụta.

Akụkụ nke Abụọ: Mmanụ Ala—Ụkpụrụ Ochie nke Narị Afọ

Mmanụ ala a na-esi na mmanụ ala apụta, ọ na-enye uru atọ dị mkpa: nnweta zuru ụwa ọnụ, ọnụ ala dị ala, na ike dielectric dị mma.

Agbanyeghị, o nwere oke ike dị n'ime ya. Ọkụ ya dị obere—ihe dị ka 145°C ruo 160°C—na-akpata ihe egwu ọkụ n'ebe ndị mmadụ bi. Ọ na-emebi nwayọ nwayọ, ọ na-abụkarị naanị pasent 30, nke pụtara na mwụfu nwere ike ibute mmebi gburugburu ebe obibi ogologo oge. Dịka ngwaahịa mmanụ ala, ọ gaghị emegharị.

Akụkụ nke Atọ: Eke Esters—Ihe Ọzọ Maka Akwụkwọ Ndụ

E si na soybean, rapeseed, na mmanụ ihe oriri ndị ọzọ nweta, esters eke apụtala dị ka ihe nnọchi anya kachasị.

Nchekwa Ọkụ.Ebe ọkụ karịrị 300°C—ihe karịrị okpukpu abụọ nke mmanụ ala—na-eme ka ha dị mma maka nrụnye obodo na ime ụlọ.

Ndakọrịta Gburugburu Ebe Obibi.Ha na-adị mfe ire ere, na-erute ọnụego mbibi nke pasent 97 ma ọ bụ karịa n'ime izu ole na ole.

Ndụ Mkpuchi Agbatịworo Agbatị.Akwụkwọ e tinyere n'ime ester eke nwere ike ịdịru ogologo oge karịa nke dị na mmanụ mineral n'okpuru nrụgide okpomọkụ yiri nke ahụ. Ester eke na-amịkọrọ mmiri gabigara ókè nke ga-emebi akwụkwọ ma mepụta njikọ nchebe na molekul cellulose.

Nnyocha ndị a kwadoro uru ndị a. Na 100°C ruo ogologo oge, ester eke nọgidere na-enwe voltaji mmebi dị elu karịa mmanụ mineral ebe ọ na-egosipụta ike nrụgide dị elu na iguzogide nrụgide siri ike karị.

Akụkụ nke Anọ: Karịa Esters Eke—Esters Sịntetik na Teknụzụ Na-apụta

Maka ihu igwe oyi na-atụ oke na ọkwa voltaji kachasị elu, esters sịntetik na-enye nkwụsi ike oxidation ka mma na arụmọrụ dị ala ma na-ejigide uru gburugburu ebe obibi.

Akụkụ kachasị ọhụrụ gụnyere nanotechnology. Titanium dioxide nanoparticles nwere ike ibelata ebe mmiri si -5°C ruo -32°C, na-eme ka ojiji oyi-ihu igwe dị. Hexagonal boron nitride nanosheets na-eme ka ike okpomọkụ dịkwuo mma ruo pasent 40. Ihe mejupụtara ígwè na ọla kọpa na-eme ka voltaji mgbawa dịkwuo elu site na pasent 32. Mgbanwe ndị a na-atụ aka n'ọdịnihu ebe esters na-adakọ ma ọ bụ karịa mmanụ mineral na ngalaba arụmọrụ ọ bụla.

Nkebi nke Ise: Ihe Ndị A Ga-atụle Maka Ndị Zụrụ

Gburugburu Ngwa.Maka ebe dị n'ime ụlọ, n'obodo ukwu, ma ọ bụ n'ebe gburugburu ebe obibi dị, esters sitere n'okike na-akwado uru ha site na nchekwa ọkụ na mbelata ibu ọrụ.

Ihu igwe.Ester eke nwere ike ịdị elu karịa mmanụ mineral, nke nwere ike imetụta oyi n'oge oyi. Teknụzụ mgbakwunye na-ebelata oghere a.

Ọnụ ego na uru ndụ.Ester eke na-eri ihe karịa na mbụ, mana ndụ mkpuchi ogologo oge nwere ike ibelata ọnụ ahịa nwe ihe niile ruo ọtụtụ iri afọ.

Nrubeisi nke Ụkpụrụ.IEC 60296 na-ekpuchi mmanụ mineral; IEC 62770 na-ekpuchi esters eke. Ndị zụrụ kwesịrị ijide n'aka na mmiri mmiri ruru ihe achọrọ.

Mmechi

Mmanụ transformer agbanweela site na ngwaahịa mmanụ dị mfe ka ọ bụrụ mmiri dị mgbagwoju anya. Esters eke na-enye nchekwa ọkụ, ndakọrịta gburugburu ebe obibi, na ndụ mkpuchi ogologo oge nke mmanụ mineral na-enweghị ike ijikọ. Esters sịntetik na-akwalite ókè arụmọrụ karịa. Maka ndị ọkachamara n'ịzụta ihe, ịghọta nhọrọ ndị a dị mkpa maka ime mkpebi amamihe.