Gịnị bụ nha nha transformer?

 

Oke mgbanwe nke transformer na-ezo aka na oke voltaji dị n'etiti oke voltaji (HV) na oke voltaji (LV). N'ụzọ pụrụ iche, ọ na-anọchite anya oke voltaji a tụrụ aro n'akụkụ mbụ (nke a na-akpọkarị oke voltaji ma ọ bụ akụkụ ntinye) na oke voltaji a tụrụ aro n'akụkụ nke abụọ (nke a na-akpọkarị obere voltaji ma ọ bụ akụkụ mmepụta).

 

N'ime mgbakọ na mwepụ, enwere ike ịkọwa oke mgbanwe (K) nke transformer dị ka:

 

K = Voltaji a tụrụ n'akụkụ Voltaji dị elu/Voltaji a tụrụ n'akụkụ Voltaji dị ala

 

 

Kedu otu esi agbakọ oke mgbanwe nke transformer?

 

 

E nwere ọtụtụ ụzọ ngụkọ maka oke mgbanwe nke transformers:

 

 

  1. Ịgbakọ Oke Mgbanwe site na Ntụgharị Coil nke Mbụ ruo nke Abụọ:

 

Usoro: Nhazi Transformer = Mgbanwe Coil Primary ÷ Mgbanwe Coil nke Abụọ

 

Ihe atụ: Ọ bụrụ na transformer nwere ntụgharị 1,000 na coil mbụ ya na ntụgharị 2,000 na coil nke abụọ ya, oke Transformer bụ 1:2.

 

 

  1. Ịgbakọ Oke Mgbanwe site na Voltaji Ntinye na Mmepụta:

 

Usoro: Oke voltaji = Voltaji mbụ ÷ Voltaji nke abụọ

 

Ihe atụ: Ọ bụrụ na transformer nwere voltaji mbụ nke 220V na voltaji nke abụọ nke 110 V, oke voltaji ahụ bụ 2:1.

 

 

  1. Ịgbakọ Oke Mgbanwe site na Ike A Na-enye Transformer:

 

Usoro: Mgbanwe oke = akara mgbọrọgwụ (ikike nke transformer x voltaji ntinye) ÷ voltaji mmepụta

 

Ihe atụ: Ọ bụrụ na transformer nwere ike nke 1,000 VA, voltaji ntinye nke 220 V, na voltaji mmepụta nke 110 V, oke mgbanwe ahụ bụ 2:1.

 

 

  1. Mmekọrịta dị n'etiti oke ntụgharị na oke voltaji

 

Ike electromotive nke e tinyere n'ime ihe na-agbanwe agbanwe (EMF) dị na ihe na-agbanwe agbanwe nke mbụ (akụkụ ntinye) na ihe na-agbanwe agbanwe nke abụọ (akụkụ mmepụta) nke ihe na-agbanwe agbanwe kwekọrọ kpọmkwem na ọnụọgụ nke ihe na-agbanwe agbanwe nke ọ bụla. Ya mere, oke nke voltaji ntinye n'akụkụ nke mbụ na voltaji mmepụta n'akụkụ nke abụọ hà nhata nke ihe na-agbanwe agbanwe.

 

 

Mgbe ị na-agbakọ oke mgbanwe, enwere ike ịhọrọ usoro kwesịrị ekwesị dabere na paramita mgbanwe na ọnọdụ ndị a maara n'ezie.

 

Mmetụta nke oke Transformer na Sistemụ Ike

 

 

  1. Nkwụsi ike nke voltaji

 

Mgbanwe na oke mgbanwe na-emetụta nkwụsi ike voltaji nke sistemụ ike ozugbo. N'ụzọ pụrụ iche, mmụba oke mgbanwe na-eduga na mmụba voltaji, ebe mbelata oke na-akpata mbelata voltaji. N'ọrụ bara uru, a ga-achịkwa oke mgbanwe nke oke mgbanwe ahụ nke ọma iji hụ na nkwụsi ike voltaji sistemụ ahụ ka dị n'ime oke a na-anabata.

 

 

  1. Ike Mbufe Ike

 

Mgbanwe nha transformer na-emetụtakwa ikike mbufe ike nke sistemụ ahụ. Mbelata nha mgbanwe na-ebelata ugbu a nke transformer, nke nwere ike ibelata ikike ibu. N'otu oge ahụ, mgbanwe nha na-emetụta ike mmeghachi omume na sistemụ ahụ. N'ihi ya, a ga-enyocha mmetụta na ikike mbufe ike nke ọma n'oge mgbanwe nha.

 

 

  1. Ihe Ize Ndụ Nchekwa

 

Ndị na-agbanwe ihe na sistemụ ike na-ejikarị kọntin laminated eme ihe maka ịrụ ọrụ winding. Ịgbanwe oke mgbanwe chọrọ ịgbanwegharị flux magnet zuru oke nke isi ahụ. Mmezu teknụzụ na-ezighi ezi nwere ike ibute fluxing core overfluxing, na-emepụta ihe egwu nchekwa dịka ọdịda mkpuchi ma ọ bụ oke okpomọkụ akụrụngwa.

 

 

  1. Mmetụta na Ọnọdụ Ọrụ Pụrụ Iche

 

N'ọnọdụ ụfọdụ (dịka ọmụmaatụ, nnwale na mmezi sistemụ ike n'oge owuwu), ịgbanwe oke transformer nwere ike ịdị mkpa iji mee ka arụmọrụ sistemụ dịkwuo mma. Agbanyeghị, mgbanwe ndị dị otú ahụ chọrọ nyocha siri ike nke mmetụta ha na nkwụsi ike zuru oke nke sistemụ ike na nchekwa ọrụ.

 

 

A ga-ahọrọ oke mgbanwe dịka ọkwa voltaji grid, ụkpụrụ mgbanwe ibu, na ihe achọrọ maka ọrụ akụ na ụba si dị. Dịka paramita dị oke mkpa na nhazi sistemụ ike, ọrụ, na nchekwa, nhazi ezi uche nke oke transformer na-emetụta kpọmkwem nkwụsi ike voltaji, njikarịcha arụmọrụ ike, na nchekwa akụrụngwa. Mgbanwe na oke mgbanwe chọrọ nlebara anya zuru oke nke oke grid, njirimara ibu, na mmachi nnyefe akụ na ụba iji belata ihe egwu dị ka mmiri na-agagharị na ọdịda voltaji.