+86 18068001229 Kedu ihe bụ Amorphous Alloy Transformers? Uru dị mkpa nke ịhọrọ Amorphous Core Transformers
Amorphous Alloy Transformers, site na mfu ha dị oke ala na arụmọrụ ike dị elu, apụtala dị ka ihe nnọchi anya mgbanwe maka transformers ígwè silicon ọdịnala. Isiokwu a na-enyocha ụkpụrụ teknụzụ ha, uru ha, ngwa ha, na nnabata nke iwu kwadoro iji duzie mkpebi amamihe.
M.Amorphous Alloy Transformers: Nkọwa na Teknụzụ
1Mmepụta Ihe
u Isi ihe eji eme iherịbọn ígwè amorphous nke e ji ígwè mee(0.02-0.04mm ọkpụrụkpụ) e ji mee ka ọ dị jụụ nke ukwuu. Ọdịdị atọm ha na-adịghị mma (dị ka iko) na-ewepụ mfu ókèala ọka, na-eme ka arụmọrụ magnetization dịkwuo mma site na 40-60% karịa ígwè silicon.
2Nhazi ihe owuwu
naIsi:Nhazi nke akụkụ atọ nke ụkwụ ise na-ebelata harmonics nke atọ ma na-eme ka nguzogide sekit dị mkpụmkpụ dịkwuo mma site na 30%.
naNdọgharị:Mkpọpụta vacuum nke Epoxy resin (mkpuchi klaasị H, ọkwa 180°C), na-eguzogide iru mmiri, mmiri nnu, na ebu.
naỊjụ oyi:Tankị corrugated emechiri emechi nke nwere ikuku oyi eke (AN) ma ọ bụ ikuku a manyere amanye (AF), nke na-akwado ikike ibufe ihe karịrị 150%.
II.Uru Ise Dị Mkpa nke Amorphous Alloy Transformers
1.Mfu Dị Oke Ala, Ego E Gosiri na A Na-echekwa
lMfu 70-80% dị ala na-enweghị ibu:Nguzogide nke amorphous alloy dị okpukpu atọ ruo isii karịa ígwè silicon. Ọmụmaatụ: 10kV/400kVA amorphous transformer no-load loss = 215W vs. 570W maka ígwè silicon.
lTCO dị ala:N'agbanyeghị na ọ na-efu pasentị iri atọ karịa, nchekwa ike kwa afọ nke $7,000+ na-eme ka a kwụọ ụgwọ n'ime afọ atọ ruo ise.
2.Nhazi Ewu na Etiti, Nhazi Kabọn na-anaghị anọchi anya ya
lMbelata CO₂:5-8 tọn kwa afọ; SO₂ belatara site na tọn 0.1.
lOge ndụ na-adịgide adịgide:A na-echekwa otu lita mmanụ kwa kilogram nke alloy e mepụtara; 100% cores enwere ike ịmegharị.
3.Ntụkwasị Obi Dị Elu na Ọnọdụ Dị Ike
lNnwere onwe n'ime otu ihe:Ụdị SCRBH15 na-arụ ọrụ nke ọma n'okpuru THD ≤5% (ọ dị mma maka inverters PV/VFDs).
lNchedo siri ike:A na-enye ọkwa IP23 maka -40°C ruo +45°C, iru mmiri 100%.
4.Ndụ Afọ 30 na Ndozi - Enweghị Mmezi
lỊka nká nke mkpuchi nwayọ:1/3 nke mbelata nke ígwè silicon.
lNhazi enweghị mmanụ:Na-ewepụ mmiri na-agbapụta; Nlekọta okpomọkụ IoT.
5.Mkpali Amụma
lIwu maka iwepụ:China ga-akwụsị ọrụ transformers S7 ka ọ na-erule afọ 2025; òkè ahịa ≥80% maka ụdị dị elu.
lEnyemaka:Mbelata 10% maka ụdị arụmọrụ Klas 1 na ọtụtụ ógbè.
nke atọ.Ngwa Ndị Dị Mkpa na Uru Onye Ọrụ
1.Ike Mmegharị Ọhụrụ
lMgbakwunye ike anyanwụ/ikuku:Ugbo ọkụ anyanwụ nke Ningxia nke nwere ike iji ike anyanwụ 2GW chekwaa ¥1.2M/afọ site na
l belatara mfu nke enweghị ibu n'abalị.
lNchekwa ike:Na-anagide usoro ịgba ụgwọ/mgbapụta ugboro ugboro.
2.Grid Obodo
lEbe azụmaahịa:Ụlọ ahịa Shanghai enwetala uru arụmọrụ ruru pasentị iri na asatọ site na iji transformer SCBH15.
lSistemụ metro:Guangzhou Line 18 na-eji ụdị amorphous akọrọ na-adịghị agba ọkụ maka nchekwa dị n'okpuru ala.
3.Ojiji ụlọ ọrụ mmepụta ihe
lỤlọ ọrụ igwe ígwè:Na-akwado oke ibu ọkụ arc, na-echekwa ¥500,000/afọ.
lỤlọ ọrụ mmanụ:Ụdị ndị na-anaghị agbawa agbawa na-eme ka ọrụ ha rụọ ọrụ ruo afọ ise ma ọ bụ karịa na Xinjiang.
IV.Usoro na Ntuziaka Nhọrọ
1.Ụzọ teknụzụ
lNlekota anya nke ọma:Sistemụ DGA dị n'ịntanetị (≥95% izi ezi nke amụma mmejọ).
Ihe ndị ga-eme ka ihe dị mma:Ngwugwu Nanocrystalline ga-ebelata mfu site na 30% (azụmahịa ka ọ na-erule 2025).
2.Iwu Nhọrọ
(1)Nkọwapụta ibu dakọtara:Mee ka ihe dị mfe maka ọnọdụ ndị na-adịghị arụ ọrụ nke ọma (ịchaji EV); ígwè silicon maka ibu dị elu (ebe data).
(2)Gbakọọ TCO:Amorphous na-enye 25-30% obere ọnụ ahịa afọ 20 (ịzụta + ike + mmezi).
(3)Nyochaa asambodo:Chọọ akụkọ nyocha CTI/STL maka mmụba okpomọkụ na ule sekit dị mkpirikpi.
Mmechi
Ndị na-agbanwe agbanwe alloy amorphous na-eduga ahịa ahụnchekwa ike,nkwado,na ntụkwasị obi, na-akwalite mmezi grid na nkwalite ụlọ ọrụ mmepụta ihe. A na-atụ anya na òkè ahịa ha zuru ụwa ọnụ ga-eto site na 26.8% (2023) ruo 35% site na 2026. Hazie nhọrọ na ụkpụrụ ibu na enyemaka iji mee ka ROI dịkwuo elu.