+86 18068001229 Ịghọta Nrụgide, Nguzogide, na Thermometers Fiber Optic
Ọrụ a pụrụ ịtụkwasị obi nke Transformer nke e ji mmanụ mee nke ukwuu dabere na nkwụsi ike nke mmanụ mkpuchi dị n'ime ya na okpomọkụ ikuku ya. Oke okpomọkụ bụ isi ihe na-akpata ịka nká ngwa ngwa nke mkpuchi, mmebi arụmọrụ, na n'ikpeazụ, ọdịda. Ya mere, nlekota okpomọkụ bụ otu n'ime akụkụ kachasị mkpa na nke dị mkpa nke ọrụ na mmezi nke transformer. Site na dial igwe ọdịnala ruo na sistemụ eriri optic ọgụgụ isi nke oge a, akụkọ ihe mere eme nke mmepe temometa bụ mgbanwe nke teknụzụ nlekota transformer site na nlele na-adịghị mma ruo na ịdọ aka ná ntị mbụ.
Isiokwu a ga-akọwapụta ụdị temometa a na-ejikarị eme ihe na transformers ndị e tinyere mmanụ n'ime ha n'ụzọ zuru ezu ma nye nyocha miri emi nke ụkpụrụ ọrụ ha na ọnọdụ ojiji ha.
Isi nke 1: "Osisi Ezinụlọ" nke Temometa - Nleba Anya zuru ezu na Ụdị Isi Atọ
Dabere na ụkpụrụ nha na ebe nrụnye, a na-ekewa temometa maka transformers ndị e mikpuru na mmanụ n'ime ụdị atọ ndị a. Ha niile na-emepụta netwọk nlekota akụkụ atọ site na okpomọkụ mmanụ dị elu ruo na ebe ọkụ na-agbagharị.
- Temometa Ụdị Nrụgide (Temometa Ọgụgụ N'ebe Dị Anya)
Ụkpụrụ Ọrụ: Nke a bụ ngwa ọrụ igwe ochie nke dabere na mgbasawanye okpomọkụ/mkpọchi na nnyefe nrụgide mmiri/gas. Sistemụ ahụ nwere akụkụ atọ:
Bọlbụ Okpomọkụ (Sensọ): A na-etinye ya n'ime mmanụ dị n'elu tankị transformer, jupụta ya na ihe na-eme ka okpomọkụ dị (dịka ọmụmaatụ, mmiri mmiri, gas, ma ọ bụ mmiri mmiri na-esi obere).
Tubọọlụ Capillary: Tubọọlụ ígwè dị ogologo, dị gịrịgịrị nke na-ejikọ bọlbụ ahụ na isi ihe nlele, nke e ji ihe na-ebuga nrụgide jupụta.
Isi Ihe Nlele (Ihe Ngosi): E tinyere ya n'elu mgbidi tankị transformer ma ọ bụ kabinet njikwa, nke nwere ike ịdị mita site na bọlbụ ahụ. Isi ya bụ tube Bourdon - tube ígwè gbagọrọ agbagọ, nke na-agbanwe agbanwe. Mgbe bọlbụ ahụ kporo ọkụ, a na-ebufe mgbanwe nrụgide dị n'ime site na capillary gaa na tube Bourdon, na-eme ka ọ gbagọọ agbagọ. Mgbanwe a na-ebugharị ihe ntụaka site na usoro njikọ, na-egosi okpomọkụ.
Njirimara Ndị Dị Mkpa:
Ọ bụ naanị igwe eji arụ ọrụ, ọ chọghị ike mpụga, ezigbo mgbochi megide nnyonye anya elektrọnik, ntụkwasị obi dị elu.
Enwere ike itinye isi ihe nlele site na ebe dị anya maka ịgụ ihe dị n'ógbè ahụ nke ọma.
A na-ejikarị kọntaktị 1-2 a pụrụ ịgbanwe agbanwe maka ọrụ mkpu oke okpomọkụ na ọrụ ngagharị.
Izi ezi na ọsọ nzaghachi dị nwayọ ma e jiri ya tụnyere ụdị eletrọniki, tube capillary na-adịkwa mfe imebi.
Ngwa nkịtị: Ngwa nlekota na mkpu bụ isi maka okpomọkụ mmanụ dị elu, ihe dị ka ihe a na-ahụkarị na transformers niile e tinyere mmanụ n'ime.
- Ihe nchọpụta okpomọkụ na-eguzogide ọgwụ (RTD, dịka ọmụmaatụ, PT100)
Ụkpụrụ Ọrụ: Dabere na njirimara na nguzogide onye na-eduzi ihe na-agbanwe ka okpomọkụ na-aga. Ihe a na-ahụkarị bụ temometa nguzogide platinum, nke PT100 na-egosi nguzogide nke 100 ohms na 0°C. Nguzogide ya na-agbanwe kpọmkwem na n'usoro na okpomọkụ.
Akụkụ Sistemụ:
Platinum RTD Probe: E tinyere ya n'ime olulu temometa dị n'elu transformer ahụ, e tinyere ya n'ime mmanụ.
Atụ Àkwà Mmiri na Ihe Mgbasa Ozi: A na-etinyekarị ya n'ime otu njikwa nwere ọgụgụ isi. Usoro sekit ziri ezi na-atụ ihe mgbochi PT100 ma na-agbanwe ya ka ọ bụrụ akara ugbu a 4-20mA ma ọ bụ akara dijitalụ.
Njirimara Ndị Dị Mkpa:
Izi ezi nha dị elu, enwere ike ibufe akara ngosi n'ebe dị anya, ezigbo mgbochi mkpọtụ.
Mmepụta bụ akara eletriki ọkọlọtọ, nke a na-ejikọta ya na nyiwe akpaaka dịka SCADA (Njikwa Nlekọta na Nnweta Data) na DCS (Sistemụ Njikwa Kesaa) maka nlekota etiti dịpụrụ adịpụ.
A na-etinyekarị ya n'akụkụ temometa ụdị nrụgide, nke na-arụ ọrụ dị ka ụzọ a na-anaghị emegharị emegharị ma ọ bụ nke dị elu maka nlekota na ndekọ okpomọkụ mmanụ n'ebe dị anya.
Ngwa nkịtị: A na-eji ya maka nnyefe site n'ebe dị anya na nlekota dijitalụ nke okpomọkụ mmanụ dị n'elu, isi ihe dị mkpa nke obere ọdụ ụgbọ mmiri akpaaka nke oge a, nke na-enweghị onye na-elekọta.
- Sistemụ Ntụle Okpomọkụ nke Fiber Optic (Ntụle "Ebe Na-ekpo ọkụ" Kachasị Elu)
Ụkpụrụ Ọrụ: Nke a bụ teknụzụ kachasị kpọmkwem na nke kachasị elu maka nlekota okpomọkụ na-agbagharị agbagharị. Ọ dabere na physics nke Fiber Bragg Gratings.
Ihe mmetụta eriri Bragg Grating (FBG): A na-ede mgbanwe oge na index refractive (grating) n'ime akụkụ nke eriri anya pụrụ iche site na iji laser. Isi ihe dị na ya: A na-egosipụta ìhè nke ogologo ebili mmiri kpọmkwem (ogologo ebili mmiri Bragg), a na-agbanwekwa ogologo ebili mmiri a n'usoro na mgbanwe na okpomọkụ (ma ọ bụ nrụgide) na ebe grating ahụ dị.
Usoro Nha: E tinyere eriri eriri optic dị nro nke nwere ọtụtụ ihe mmetụta FBG ozugbo n'etiti akwa mkpuchi nke windings voltaji dị elu na ebe kacha ekpo ọkụ n'oge nrụpụta transformer. Sistemụ ahụ na-ewepụta ìhè broadband, sitekwa na inyocha ogologo ebili mmiri akọwapụtara site na grating ọ bụla, ọ nwere ike nweta okpomọkụ zuru oke n'oge dị iche iche n'ime winding ahụ.
Njirimara Ndị Dị Mkpa:
Ntụle ozugbo nke okpomọkụ ebe ọkụ na-agbagharị agbagharị, ọ bụghị atụmatụ na-apụtaghị ìhè. Data bụ nke kacha bụrụ eziokwu ma bụrụ nke a pụrụ ịtụkwasị obi.
Nchekwa dị n'ime: E ji silica mee eriri anya, ihe mkpuchi, ihe na-eguzogide oke voltaji, na ihe na-anaghị akpata nsogbu elektrọnik, na-arụ ọrụ nke ọma n'ọhịa EM siri ike.
Nha nha kesara: Otu eriri nwere ike ịnabata ọtụtụ ebe mmetụta, na-eme ka o kwe omume ịmepụta maapụ okpomọkụ zuru oke nke winding.
Ihe na-eme ka ihe dị mkpa maka transformer "Dynamic Rating" na nyocha ndụ niile.
Ngwa A Na-ejikarị Eme Ihe: Transformers buru ibu, dị oke mkpa (dịka ọmụmaatụ, EHV, transformers converter), ọdụ ndị nwere ọgụgụ isi nke chọrọ njikwa ikike ibu.
Isi nke 2: Nkọwapụta Isi Echiche - Okpomọkụ Mmanụ Dị Elu vs Okpomọkụ Na-agbagharị
Nke a bụ echiche dị oke mkpa na ebe mmalite maka ịhọrọ ụdị temometa.
Okpomọkụ Mmanụ Elu: Na-atụ okpomọkụ mmanụ dị n'elu tankị ahụ. Ọ na-egosipụta ibu okpomọkụ nke transformer dum mana ọ na-enwe oge okpomọkụ. Mgbe ibu gbanwere, okpomọkụ na-agbanwe ngwa ngwa, okpomọkụ mmanụ na-esochi ya. Ụdị nrụgide na temometa RTD na-atụ nke a.
Okpomọkụ Ebe Na-ekpo Ọkụ: Na-ezo aka n'ebe kachasị ọkụ na transformer dum, nke a na-ahụkarị n'elu nke obere voltaji winding. Ọ bụ paramita kachasị mkpa nke na-ekpebi ọnụego ịka nká na ikike ibu. Ụzọ ọdịnala enweghị ike ịtụ ya ozugbo, kama ọ dabere na Winding Okpomọkụ Ihe Ngosi (WTI) nke na-eme ka ọ dị ka ihe atụ/atụmatụ site na iji "ndozi okpomọkụ mmanụ dị elu + ugbu a." Nha nha eriri optic bụ naanị teknụzụ nwere ike ịtụ ya ozugbo na nke ziri ezi.