+86 18068001229 Ọmụmụ nke Transformer Ụdị Akọrọ
Ọrụ Nhazi Isi: 'Skeleton' nke Transformer
Isi ihe dị n'ime sekit magnet nke transformer. Ọdịdị ya na-emetụta kpọmkwem mfu na ọkwa mkpọtụ nke transformer ahụ.
Nhọrọ na Ịkpụcha Ihe: A na-ejikarị ígwè silikọn dị elu nke a na-akpọ "cold rocked" nke a na-akpọ "laser". A na-ejikarị nke a eme ihe iji belata mfu hysteresis. A na-eji eriri ịkpụcha ígwè ahụ ka ọ dị mma.
Ịkwakọba na Ịkpakọ: Usoro ọgbara ọhụrụ na-ejikarị "step-lap" stacking na nhazi nkwonkwo nke ogo 45 zuru oke. Nke a na-ebelata mfu na nkwonkwo na oghere ikuku nke ọma, si otú a na-ebelata mfu na-enweghị ibu, ọkụ eletrik na-enweghị ibu, na mkpọtụ isi. A na-eji ihe pụrụ iche ejide isi ahụ nke ọma ma mgbe ụfọdụ a na-ekpuchi ya na ihe mmiri na-anaghị eguzogide nchara.
Mkpọchi na Mkpuchi Coil: 'Obi' nke Transformer
Ihe ndị a na-agbagharị agbagharị na-emepụta sekit eletriki nke transformer, na-eme ka usoro mmepụta ha dị oke mkpa.
Usoro Ngagharị: A na-ejikarị igwe ngagharị dị elu na-agbagharị agbagharị nke nwere ike ịgbagharị agbagharị nke nwere ike iguzogide nrụgide na ike, nke dị oke mkpa maka ikike iguzogide obere sekit nke transformer. Dabere na ikike na voltaji, obere voltaji (LV) nwere ike ịbụ nke nwere ike ibute mmerụ ahụ ma ọ bụ nke nwere ike ibute mmerụ ahụ.
Ndị Na-eduga Mkpọchi: A ghaghị itinye ndị na-eduga mkpọchi maka HV n'ọnọdụ ziri ezi dịka atụmatụ si dị, ya na ogologo kwesịrị ekwesị, ihe e ji agbakọta, na ihe mkpuchi mkpuchi a pụrụ ịdabere na ya iji gbochie nsogbu dịka sekit dị mkpirikpi ma ọ bụ nsogbu mgbakọ.
Nhazi mkpuchi: 'Akwa nchekwa' dị oke mkpa
Nke a dị oke mkpa karịsịa maka transformers akọrọ nke resin cast.
Ịkpọcha tupu e kpoo ya: A na-akpọcha ihe ndị e ji emechi ihe na ihe ndị ọzọ e ji ekpuchi ihe tupu e tinye ha iji wepụ mmiri mmiri.
Ịkpụcha Resin Vacuum: Nke a gụnyere ịwụsa ngwakọta resin epoxy n'ime ebu nwere windings n'okpuru ebe ikuku dị. Vacuum ahụ na-ewepụ afụfụ ikuku, na-eme ka resin ahụ banye kpamkpam ma mepụta usoro mkpuchi siri ike, nke bụ isi ihe dị mkpa iji chịkwaa mwepụ nke akụkụ ụfọdụ.
Ịgwọ: Mgbe a kpụchara ya, a na-ekpo ọkụ nkebi ahụ n'okpuru ọnọdụ okpomọkụ a na-achịkwa nke ọma iji gwọọ resin ahụ. Ịkpụcha ya na ịgba ya ọkụ nke ọma na-eme ka transformer ahụ ghara iguzogide mmiri, ọ naghị agba ọkụ, ma nwee ike dị elu n'ime ya.
Mgbakọ na Nnwale: 'Nlele Ahụike' Ikpeazụ
Nke a gụnyere ịchịkọta windings ndị a na-ekpuchighị ekpuchi, isi, na ihe ndị ọzọ.
Nnwale Nha nha na Nnwale Nguzogide Ntụgharị
Nnwale Mfu Ibu na Mfu Ibu Na-enweghị Ibu: Na-enyocha ọkwa arụmọrụ ike. Dịka ọmụmaatụ, transformer ụdị akọrọ nke SCB13 nwere obere mfu ibu na-enweghị ibu ma ọ bụ ibu ma e jiri ya tụnyere ụdị ochie.
Nnwale Ike Voltaji Ejiri Mee Ihe na Ike Voltaji Ejiri Mee Ihe: Na-enyocha ike mkpuchi isi na nke dị n'etiti ntụgharị.
Nnwale Mwepụ Akụkụ: Usoro mmepụta dị elu nwere ike ibute obere ọkwa mwepụ akụkụ.
Mgbakọ Core & Coil: A na-ejikọta isi na coils, a na-emekwa njikọ dị n'ime.
Ntinye na Mgbakwunye Ikpeazụ: Nke a gụnyere itinye fan oyi, ngwaọrụ njikwa okpomọkụ, ihe nchekwa, wdg.
Nnwale Ndị A Na-emebu: Ihe ndị a dị mkpa iji hụ na transformer ahụ ruru ụkpụrụ na nkọwapụta imewe.
Nkwakọ ngwaahịa na Mbupu
N'ikpeazụ, dabere na nha nke transformer na anya mbupu ya, a na-ahọrọ ihe na ụzọ kwesịrị ekwesị maka nkwakọ ngwaahịa (dịka ọmụmaatụ, igbe osisi ma ọ bụ ígwè) iji hụ na e chebere ngwaahịa ahụ pụọ na mmebi n'oge njem.
Nchịkọta
N'ikwu ya n'ụzọ dị mfe, imepụta transformer dị elu nke ụdị akọrọ bụ nsonaazụ nke njikọta nke imewe, ihe, ọrụ aka, na njikwa mma. Nlebara anya nke ọma nke onye nrụpụta na nhọrọ ihe (dịka ọmụmaatụ, ígwè silicon dị elu, ọla kọpa nwere ike ịrụ ọrụ nke ọma, mkpuchi mma) na usoro nrụpụta ọ bụla (dịka ọmụmaatụ, nhazi isi, winding coil, nhazi mkpuchi) na-ekwe nkwa arụmọrụ na ntụkwasị obi nke ngwaahịa ikpeazụ.