+86 18068001229 Ngwaahịa - Ihe Mmecha
Na 2024, anyị zigara transformer 12 MVA na Philippines. Transformer a nwere ike nke 12,000 KVA ma na-arụ ọrụ dị ka transformer na-agbada nzọụkwụ, na-agbanwe voltaji mbụ nke 66 KV ka ọ bụrụ voltaji nke abụọ nke 33 KV. Anyị na-eji ọla kọpa eme ihe maka ihe na-agbagharị n'ihi ike eletrik ya dị elu, arụmọrụ okpomọkụ ya, na iguzogide nchara.
E ji teknụzụ ọgbara ọhụrụ na ihe ndị dị elu mepụta ya, transformer ike 12 MVA anyị na-enye ntụkwasị obi na ogologo oge pụrụ iche.
Na JZP, anyị na-ekwe nkwa na transformer ọ bụla anyị na-ebuga ga-enweta ule nnabata zuru oke. Obi dị anyị ụtọ na anyị anọgidewo na-enwe ndekọ enweghị ntụpọ zuru oke ruo ihe karịrị afọ iri. Ndị Na-agbanwe Ike E mepụtara ha ka ha mezuo ụkpụrụ siri ike nke IEC, ANSI, na nkọwapụta mba ụwa ndị ọzọ dị mkpa.
Oke nke ọkọnọ
Ngwaahịa: Ihe na-agbanwe Ike nke A Na-etinye Mmanụ
Ike a tụrụ anya ya: Ruo 500 MVA
Voltaji Mbụ: Ruo 345 KV
Nkọwapụta Nkà na ụzụ
Nkọwapụta na mpempe akwụkwọ data nke mgbanwe ike MVA 12
| Ụdị nlereanya | SFZ11-12 MVA-66/33KV |
| Ụdị | Transformer ike mikpuru 0il |
| Ọkọlọtọ | IEC60076 |
| Ike enyere ọkwa | 12000 KVA |
| Ugboro ole | 60HZ |
| Oge nkewa | 3 |
| Ụdị oyi | AKWỤKWỌ NA-ENWEGHỊ IKE |
| Voltaji Mbụ | 66 KV |
| Voltaji nke abụọ | 33 KV |
| Ihe Ntụgharị | Ọla kọpa |
| Otu Vektọ | Ynd1 |
| Impedance | 10% |
| Pịa Mgbanwe | OLTC |
| Oke ịpị ọkpọ | ±8*1.25% |
| Ngwa | Ọkọlọtọ |
| Okwu ndị e kwuru | Enweghị |
Usoro oyi nke Transformer nke e ji mmanụ mee Ọ na-abụkarị iji mmanụ transformer dị ka isi ihe na-eme ka ihe dị jụụ. Mmanụ a na-arụ ọrụ abụọ bụ isi: ọ na-arụ ọrụ dị ka ihe na-egbochi ọkụ eletrik ma na-enyere aka iwepụ okpomọkụ sitere na transformer. Lee ụfọdụ ụzọ oyi a na-ejikarị eme ihe na transformer ndị e tinyere mmanụ:
1. Mmanụ Ikuku Okike nke Okike (ONAN)
● Nkọwa:
N'ụzọ a, a na-eji convection eke agbasa mmanụ n'ime tankị transformer.
o Mmanụ ahụ na-amịkọrọ okpomọkụ nke winding transformer na-emepụta, nke na-ebili ma na-ebufe okpomọkụ ahụ na mgbidi tankị ahụ.
o A na-agbasa okpomọkụ ahụ n'ime ikuku gbara ya gburugburu site na ikuku ikuku sitere n'okike.
● Ngwa:
o Dabara adaba maka obere transformers ebe okpomọkụ a na-enweta anaghị agafe oke.
● Nkọwa:
o Usoro a yiri ONAN, mana ọ gụnyere ikuku a na-amanye.
o A na-eji fan afụ ikuku n'elu elu radiator nke transformer ahụ, na-eme ka usoro oyi dịkwuo mma.
● Ngwa:
o A na-eji ya eme ihe na transformers dị ọkara ebe achọrọ ka e mee ka oyi dị jụụ karịa ikuku nkịtị.
● Nkọwa:
N'ime OFAF, a na-eji ọkpọkọ na fan agbasa mmanụ na ikuku.
o Pampụ mmanụ na-ekesa mmanụ ahụ site na transformer na radiators, ebe fan na-amanye ikuku n'ofe radiators.
● Ngwa:
o Dabara adaba maka nnukwu transformers ebe convection eke anaghị ezu oke maka oyi.
● Nkọwa:
o Usoro a na-eji mmiri eme ihe dị ka ihe ọzọ na-eme ka ọ dị jụụ.
o A na-ekesa mmanụ site na ihe ndị na-agbanwe okpomọkụ ebe mmiri na-eme ka mmanụ jụọ oyi.
o A na-eme ka mmiri ahụ jụọ oyi site na usoro dị iche.
● Ngwa:
A na-eji ya eme ihe n'ime nnukwu transformers ma ọ bụ nrụnye ebe oghere maka ikuku oyi pere mpe ma dịkwa mkpa maka arụmọrụ ka elu.
● Nkọwa:
o Yiri nke OFAF, mana ọ na-enwe mmanụ na-aga nke ọma.
o A na-esi n'ọwa maọbụ ọkpọkọ pụrụ iche eduzi mmanụ ahụ iji mee ka ọ dị mma n'ebe ụfọdụ dị ọkụ n'ime transformer ahụ.
● Ngwa:
o A na-eji ya eme ihe na transformers ebe achọrọ ka oyi dị iche iche wee jikwaa nkesa okpomọkụ na-adịghị mma.
● Nkọwa:
o Nke a bụ usoro oyi dị elu ebe a na-eduzi mmanụ ka ọ na-agafe n'ụzọ ụfọdụ dị n'ime transformer ahụ, na-ahụ na a na-eme ka ọ dị jụụ nke ọma.
o A na-ebufe okpomọkụ ahụ gaa na mmiri site na ihe ndị na-agbanwe okpomọkụ, a na-amanye ya ịgbasa okpomọkụ nke ọma.
● Ngwa:
o Ọ dị mma maka transformers buru ibu ma ọ bụ nke nwere ike dị elu n'ọrụ ụlọ ọrụ mmepụta ihe ma ọ bụ ọrụ ebe njikwa okpomọkụ ziri ezi dị oke mkpa.
2. Mmanụ Eke nke Ebu n'Ikuku (ONAF)
3. Mmanụ a na-amanye n'ikuku (OFAF)
4. Mmiri a na-amanye mmanụ (OFWF)
5. Mmanụ na-eduzi ikuku (ODAF)
6. Mmiri a na-eduzi mmanụ (ODWF)