+86 18068001229 Transformers JZP Single-Phase Pad-Mounted: Injinịa nkenke maka Nkesa Ike A Pụrụ Ịtụkwasị Obi
Emebere mgbanwe JZP nke otu usoro nke nwere pad arụnyere n'elu ka ha gafere ọkọlọtọ ụwa ebe ha na-enye mgbanwe na ogologo oge na-enweghị atụ maka ụdị dị iche iche. Nkesa Ike mkpa. Emebere ya ka o rube isi ma gafereỤkpụrụ ANSI, IEEE, DOE, CSA, na NEMA, transformers ndị a nwere atụmatụ nchekwa dị elu na owuwu siri ike, na-ahụ na arụmọrụ kachasị mma na ngwa ụlọ ọrụ mmepụta ihe, azụmahịa, na ebe obibi.
;Isi Atụmatụ na Nkọwapụta;
;Nrubeisi na Nchekwa;
- Asambodo zuru oke naNdepụta UL/cUL, CSA, ma nwalee yaANSI IEEE C57.12.00,CSA C22.2 Nke 66, naIhe nrịbama arụmọrụ DOE 2016.
- Ejiri aka meeMmiri Envirotemp FR3™maka nchekwa ọkụ ka mma na nchekwa gburugburu ebe obibi, tinyere nhọrọ mmanụ ihe mkpuchi mineral ọdịnala.
;Nhazi ahaziri ahazi;
- ;Oke ikike: 15–250 kVA, nke a na-agbanwe agbanwe maka ojiji site na obere sistemụ obibi ruo na ibu ọrụ ụlọ ọrụ dị arọ.
- ;Mgbanwe voltaji:
- Voltaji ndị bụ isi: 34.5 kV–7.2 kV (a pụrụ ịhazi ya).
- Voltaji nke abụọ: 120–600 V (120-240 V, 240-480 V, 347/600 V, ma ọ bụ ngwọta ahaziri ahazi).
- ;Nhọrọ nri: Nhazi mkpọchi ma ọ bụ radial iji kwekọọ na ihe achọrọ maka grid.
;Ọrụ siri ike;
- ;Ihe Ụlọ: Ígwè dị nro ma ọ bụ nhọrọTankị ígwè anaghị agba nchara 304maka iguzogide nchara n'ebe siri ike.
- ;Mkpuchi na Jụụ: Sistemụ mkpuchi dị elu na oyi ikuku convection eke maka njikwa okpomọkụ a pụrụ ịtụkwasị obi.
- ;Ọkwa BIL: 30–150 kV, na-eme ka o doo anya na ọ ga-eguzogide nrụgide voltaji.
;Arụmọrụ na Arụmọrụ;
- Nhazi arụmọrụ dị elu nke dabara naỤkpụrụ ike DOE 2016, na-ebelata ọnụ ahịa ọrụ.
- Mkpọchi ndị na-ebelata ihe mgbu na isi magnet kachasị mma na-eme ka nchekwa ike dịkwuo mma.
;Ngwa na Njikọta;
- Dakọtara na ụdị dị elu dịkaABB, Eaton, na Qualitrolmaka ọrụ ka mma (dịka ọmụmaatụ, sistemụ nlekota, nchedo mmụba).
- Ihe mgbanwe ọkpọkọ enwere ike ịhazi (mgbanwe 2 × 2.5%) maka nhazi voltaji ziri ezi.
;Mmepụta na Nnyefe;
- ;Ike: N'eluNkeji 600/ọnwa, na-ahụ na mgbanwe ngwa ngwa na-enweghị imebi àgwà.
- ;Etiti oge: Nnyefe ngwa ngwa naIzu anọ–8, nke usoro mmepụta dị mfe na-akwado.
;Gịnị mere ị ga-eji họrọ JZP?;
A na-emepụta transformers JZP maka ogologo oge, nkwado, na mgbanwe. Ma ọ bụ ịkwalite sistemụ ochie ma ọ bụ itinye akụrụngwa ọhụrụ, ngwọta anyị na-ebute ụzọnchekwa, arụmọrụ, na nrubeisiNhọrọ ndị a pụrụ ịgbanwe agbanwe—site na ọkwa voltaji ruo ihe ndị e ji arụ ọrụ—hụ na ejikọtara ha nke ọma na grid ike ọ bụla.
Maka akwụkwọ teknụzụ zuru ezu ma ọ bụ iji tụlee ihe achọrọ maka ọrụ, kpọtụrụ ndị otu injinia JZP taa.