+86 18068001229 N'ime Transformer Atọ nke Ejiri Pad Mee: Ndakọrịta Teknụzụ maka Ngwọta Ike nke Oge A

N'ihe gbasara akụrụngwa eletriki, transformers nke nwere usoro atọ bụ ndị dike a na-akpọghị aha na-eme ka ọ dị irè. Nkesa IkeIsiokwu a na-enyocha nhazi ime ha, na-akọwapụta ihe ndị dị ịtụnanya dị na injinia nke mere ka ha dị oke mkpa maka ojiji ike mmepụta ihe, azụmahịa, na ike mmeghari ohuru.
1. Mgbakọ Isi: Obi Magnetik
E ji ihe e ji ígwè silicon mee ka isi transformer ahụ dị n'etiti iji belata mfu nke ikuku ọkụ ma mee ka arụmọrụ nke ikuku ọkụ magnet dịkwuo mma. N'adịghị ka transformers ụdị otu ọdịnala nwere sekit magnet dịpụrụ adịpụ, atụmatụ ọgbara ọhụrụ na-eji usoro isi akụkụ atọ (dịka egosiri na
), ebe akụkụ etiti na-anabata usoro njikọta nke usoro atọ niile. Nhazi a na-ebelata ojiji ihe ma na-eme ka okpomọkụ kwụsie ike, nke dị oke mkpa maka ngwa ike dị elu dịka njikọta ugbo anyanwụ.
Isi Atụmatụ:
Ihe owuwu e ji laminate rụọ: Na-ebelata mfu hysteresis ruo 30% ma e jiri ya tụnyere isi siri ike.
Ọwa Mmiri Oyi: Ọwa mmanụ agbakwunyere (n'ụdị mmanụ e mikpuru) na-eme ka okpomọkụ dị otu.
2. Ndọgharị: Ndị na-eduzi ihe ndị e ji nlezianya rụọ
A haziri windings ahụ nke ọma iji dozie nkesa voltaji na iguzosi ike n'ezi ihe igwe:
Ngwugwu Voltaji Dị Elu (HV): A na-ejikarị ọla kọpa ma ọ bụ aluminom conductors kpuchie ya, a na-etinyekwa ya na epoxy-resin ma ọ bụ Nomex, ma tinye ya n'èzí windings dị ala (LV) maka nhazi voltaji kacha mma.
Mkpọchi LV: Mkpọchi dị obere, nke a na-etinye n'ime akwa dị nso na isi iji belata mmeghachi omume ntapu.
Ihe ọhụrụ:
Mkpọchi LV nke Foil-Wound: Belata ike sekit dị mkpirikpi n'oge ihe omume nwa oge, dịka nyocha ihe dị na njedebe (FEA) si kwado ya.
Nhazi Mgbanwe Oge: Mee ka ndakọrịta na sistemụ grid smart nke chọrọ njikwa voltaji na-agbanwe agbanwe.
3. Sistemụ Jụụ: Ịkwado arụmọrụ
Transformers nke nwere usoro atọ nke pad na-eji usoro oyi dị elu:
ONAN (Mmanụ na Ikuku na-eke): Ntugharị sitere n'okike na-ekesa mmanụ transformer site na radiators.
ONAF (Mmanụ sitere n'okike nke ikuku): Ndị na-efe efe na-eme ka ikuku na-aga nke ọma maka ikike ibu dị elu, nke zuru oke maka ebe ọrụ mmepụta ihe.
Ọmụmụ Ihe:
Transformers VFI (Vacuum Fault Interrupter) nke Eaton na-ejikọta ngalaba ndị e mechiri emechi na teknụzụ break a na-ahụ anya, na-ahụ na nchekwa na nrubeisi na ụkpụrụ IEEE 1584 arc-flash dị mma.
4. Atụmatụ Nchedo: Nchekwa Mbụ
Valvụ Mgbochi Nrụgide: Chebe megide nrụgide gabigara ókè nke nsogbu dị n'ime na-akpata.
Buchholz Relay: Na-achọpụta mkpokọta gas site na mmebi nke mkpuchi, na-egbochi ọdịda dị egwu.
Nlekota Amamihe: Ụdị ndị IoT nwere ike ime (dịka ọmụmaatụ, usoro PRCLF nke Eaton) na-enye data oge niile gbasara okpomọkụ, ibu, na ahụike mkpuchi site na sistemụ SCADA.
5. Nhazi ihe owuwu: Ogologo oge na-ezute obere ihe
Ihe mkpuchi na-eguzogide ire ere: Ígwè galvanized ma ọ bụ ihe ndị mejupụtara ya na-eguzogide gburugburu siri ike.
Mmesi Ike nke Ala Ọma Jijiji: Ihe nkwado ndị e ji ebuli elu na-eme ka ebe ndị ala ọma jijiji na-adịkarị kwụsie ike.
Mgbakọ Modular: Na-eme ka nrụnye na mmelite n'ọdịnihu dị mfe, dị oke mkpa maka ọrụ ike mmeghari ohuru.
Ngwa na-akwalite ihe ọhụrụ
Njikọta Ike Mmegharị: Transformers ndị na-arụ ọrụ maka ugbo anyanwụ/ikuku 5MW+ na-eji ihe mgbochi nsogbu oghere iji jikwaa ọkụ eletrik dị elu.
Ebe Nchekwa Data: Nhazi dị obere, nke na-anaghị eme mkpọtụ na-eme ka ike na-akwụsị akwụsị yana njikwa voltaji ±1%.
Arụmọrụ Mmepụta Ihe: Ntụle impedance ahaziri ahazi (dịka ọmụmaatụ, 5.75%) na-eme ka ike dị mma maka igwe dị nro.
Gịnị Mere Ị Ga-eji Họrọ Transformers Anyị Atọ Na-etinye Pad?
Arụmọrụ: >99% arụmọrụ mgbe ibu zuru oke, kwekọrọ na ọkọlọtọ IEC 60076.
Nchekwa: Ebe nchekwa ndị na-eguzogide arc na-ebelata ike mberede ka ọ bụrụ Nhazi: Dị na klaasị voltaji 10kV–34.5kV na ọkwa 50–5000kVA.
Nhazi ime nke transformer nke nwere usoro atọ a na-etinye na pad na-agwakọta injinia ziri ezi na atụmatụ nchekwa kachasị ọhụrụ, na-eme ka ọ bụrụ isi ihe dị mkpa na sistemụ ike ọgbara ọhụrụ. Ma ị na-enye ọkụ n'ụlọ ọrụ mmepụta ihe mara mma ma ọ bụ ugbo ikuku dịpụrụ adịpụ, ngwọta anyị na-enye ntụkwasị obi na mgbanwe na-enweghị atụ.
Lelee katalọgụ ngwaahịa anyị ma ọ bụ kpọtụrụ ndị injinia anyị ka ha hazie transformer maka ọrụ gị na-esote.