+86 18068001229 Ọrụ na Ojiji nke Transformers Atọ nke A Na-etinye Mmanụ n'ime Mmiri
Ọrụ Isi
;
Mgbanwe Voltaji na Nnyefe Ike
Transformer nke Atọ nke Ejiri Mmanụ Mikpuos na-eji induction elektrọnik iji bulie ma ọ bụ belata voltaji AC, na-eje ozi dị ka akụrụngwa dị mkpa na sistemụ ike iji jikọọ grid nke ọkwa voltaji dị iche iche. Dịka ọmụmaatụ, ha na-ebuli voltaji mmepụta jenerato (dịka ọmụmaatụ, 6kV ma ọ bụ 10kV) gaa na voltaji ọkwa nnyefe (dịka ọmụmaatụ, 220kV ma ọ bụ karịa) maka nnyefe ike dị anya ma ọ bụ belata ọkụ eletrik dị elu gaa na voltaji ọkwa nkesa (dịka ọmụmaatụ, 10kV/0.4kV) maka ndị ọrụ njedebe
.
Mkpuchi na Mgbasa Okpomọkụ
Mmanụ transformer na-arụ ọrụ dị ka ihe na-egbochi ihe na ihe na-eme ka oyi dị jụụ:
Mkpuchi: Ike dielectric dị elu nke mmanụ ahụ (karịa ikuku) na-egbochi obere sekit dị n'etiti windings na cores, na-ewepụ mmiri na ihe ndị na-emerụ emerụ, ma na-ebelata ịka nká nke mkpuchi
.
Oyi: A na-ebufe okpomọkụ sitere na windings na cores na mmanụ, nke na-agbasa n'ụzọ ebumpụta ụwa ma ọ bụ site na sistemụ mmanye (dịka ọmụmaatụ, fan, pumps) na radiators ma ọ bụ elu tankị, na-eme ka okpomọkụ ọrụ dị mma (karịsịa ≤85°C maka mmanụ oyi akwa elu)
.
Nchekwa na Ịkwụsi Ike
Nguzogide Gburugburu Dị Mkpirikpi: Ihe owuwu ndị e ji mmanụ mikpuo nke ọma na-eme ka ike igwe dịkwuo mma, nke e ji ihe ndọghachi azụ gas na oghere ndị na-anaghị agbawa agbawa mee ka ha nwee ike ịhapụ nrụgide n'enweghị nsogbu n'oge mmejọ dị n'ime.
.
Iwu voltaji: Ndị na-agbanwe mgbata ma ọ bụ ndị na-apụ apụ na-agbanwe voltaji mmepụta (±5% oke) iji mee ka mgbanwe grid kwụsie ike site na njikọta ike mmeghari ohuru ma ọ bụ mgbanwe ibu kpatara
.
Mgbanwe Gburugburu Ebe Obibi
Ọrụ Elu Elu: Maka elu karịrị mita 3,000, atụmatụ ndị a gụnyere nnukwu fan oyi ma ọ bụ mmịpụta okpomọkụ kachasị mma iji kwụọ ụgwọ maka mbelata arụmọrụ oyi n'ihi obere nrụgide ikuku.
.
Teknụzụ Mkpuchi: Tankị corrugated ma ọ bụ ihe nchekwa nke dabere na kapsụl na-ebelata kọntaktị mmanụ na ikuku, na-agbatị oge mmezi yana ndụ ọrụ
.
Ngwa Ndị Dị Mkpa
Akụrụngwa Ike
Mmepụta na Ebe Nchekwa: Mee ka voltaji dịkwuo elu na ebe ọkụ eletrik (dịka ọmụmaatụ, 10kV ruo 220kV) maka nnyefe na mbelata voltaji na ebe ọkụ eletrik dị n'okpuru (dịka ọmụmaatụ, 35kV ruo 0.4kV) maka ojiji ụlọ ọrụ mmepụta ihe/obodo ukwu.
.
Njikọta Grid: Mee ka nkesa ike dị mfe n'ofe mpaghara dị iche iche, na-ahụ na enwere ike ịhazi usoro nnyefe na ọchịchọ.
Ngalaba ụlọ ọrụ na ike
Ubi Mmanụ na Ngwuputa: Nye ike kwụsiri ike maka igwe egwupụta ihe, ngwa mwepụta ihe, na ebe ndị dịpụrụ adịpụ n'ebe siri ike
.
Ọrụ Metallurgy na Kemịkal: Nye ike voltaji dị elu (dịka ọmụmaatụ, 10kV/35kV) nye sel electrolytic, oven, na moto buru ibu
.
Ọrụ Ụlọ na Ọrụ Ọha
Ike Nwa Oge: E tinyere ya n'ebe a na-ewu ihe owuwu, ihe omume, ma ọ bụ ọnọdụ mberede maka nkesa ọkụ eletrik ngwa ngwa na nke a pụrụ ịtụkwasị obi
.
Njem Ụgbọ okporo ígwè: Ike ịdọta ihe (dịka ọmụmaatụ, 35kV/1.5kV) maka sistemụ ụgbọ okporo ígwè metro na sistemụ ụgbọ okporo ígwè dị elu
.
Mmeghari ohuru na Grid smart
Njikọta Anyanwụ/Ifufe: Mee ka ike mmeghari ohuru dị ala (dịka ọmụmaatụ, 0.69kV) ruo na ọkwa ntinye grid (dịka ọmụmaatụ, 35kV) maka nri dị mma
.
Iwu Voltaji Na-arụ Ọrụ: Gbanwee mgbanwe ntinye ike kesara, na-edobe nkwụsi ike grid site na mgbanwe mgbata ozugbo
.
Ọganihu na Usoro Nhọrọ Teknụzụ
Mmelite arụmọrụ ike
Ụdị ọgbara ọhụrụ (dịka ọmụmaatụ, usoro S13/S22) na-ebelata mfu ndị na-enweghị ibu site na >30% site na nhazi isi kachasị mma (dịka ọmụmaatụ, alloys amorphous) na nhazi winding, na-agbaso ụkpụrụ GB 20052-2024.
.
Mmezi Gburugburu Ebe Obibi
Mmanụ ndị a na-ere ere: Jiri esters osisi (100% nke nwere ike ire ere, ebe ọkụ na-ere ere ≥350°C) dochie mmanụ mineral iji belata ihe egwu ọkụ na mmetụta gburugburu ebe obibi.
.
Nlekota Smart: Ihe mmetụta IoT agbakwunyere na-esochi ịdị mma mmanụ, okpomọkụ, na mwepụ akụkụ maka mmezi amụma
.
Paramita nhọrọ
Ike: 30kVA ruo 20,000kVA, yana nkeji buru ibu maka ibu ọrụ ụlọ ọrụ
.
Ụdị oyi:
ONAN (Mmiri na-eme ka oyi dị n'ime onwe ya): Obere ikike (
OFAF (Mmanụ a na-amanye/Ikuku na-ajụ oyi): Transformers nwere ikike dị elu (>20,000kVA)
.
Klas mkpuchi: Klas H (180°C) maka gburugburu ebe dị oke njọ
.
Mmechi
Transformers nke nwere usoro atọ nke mmanụ ka dị mkpa na sistemụ ike ọgbara ọhụrụ n'ihi arụmọrụ ha, ntụkwasị obi ha, na mgbanwe ha. Mmepụta ihe ọhụrụ na ihe ndị na-adịghị ize ndụ gburugburu ebe obibi, nchọpụta ihe dị mma, na imewe dị mkpụmkpụ kwekọrọ na ebumnuche nkwado zuru ụwa ọnụ, na-ahụ na ọ dị mkpa ịnọgide na-enwe mmasị na atụmatụ mgbanwe ike.