+86 18068001229 Ụdị Akọrọ Vs. Transformers Ndị A Mikpuru n'ime Mmanụ: Nduzi Ntụnyere zuru oke
I. Isi Ihe Dị Iche
1. Nhazi na Mkpuchi
Mkpuchi: Epoxy resin casting ma ọ bụ ihe mkpuchi siri ike na-abụghị nke e ji kpuchie (dịka ọmụmaatụ, akwụkwọ Nomex).
Nhazi: Isi/mgbatị a na-ahụ anya nke nwere ihe mkpuchi rọba silicone.
Transformer nke e ji mmanụ mees:
Mkpuchi: Mmanụ ester nke e si n'ime ala ma ọ bụ nke e ji aka mee; a na-emikpu ya nke ọma n'ime tankị.
Nhazi: Tankị e mechiri emechi nke nwere ihe mkpuchi poselin.
2. Ike na oke voltaji

II. Ntụnyere arụmọrụ na ọnụ ahịa
1. Ike Ịjụ oyi na ibufe ihe karịrị akarị
Arụmọrụ oyi:
Ụdị Akọrọ: Ikuku oyi sitere n'okike/mmanye (arụmọrụ pere mpe).
Mmanụ a mikpuru n'ime mmiri: Ọ na-agbasa mmanụ (ọ ka mma maka ibu dị elu na-adịgide).
Nnwere Onwe Ibu:
Ụdị Akọrọ: ≤ 1.5x ikike a tụrụ anya ya (obere oge).
Mmanụ e tinyere n'ime mmiri: 30% ibu arọ ruo otu awa.
2. Ọnụ ego na mmezi

III. Ihe Ndị Dị Mkpa n'Ojiji
1. Ihe eji eme ihe dị mkpa maka ụdị akọrọ
Nchekwa Ọkụ: Ụlọ ọgwụ, ụgbọ okporo ígwè dị n'okpuru ala, ụlọ elu dị elu (epoxy na-egbochi ire ọkụ).
Ihe mgbochi oghere: Ụlọ ndị dị n'okpuru ala, obere ọdụ ụgbọ mmiri (20% pere mpe).
Mpaghara Ndị Na-emetụta Gburugburu Ebe Obibi: Nhazi enweghị mmanụ dabara na RoHS.
2. Ihe ndị a na-ahụkarị n'ime mmanụ
Mkpa Ike Dị Elu: Ụlọ ọrụ okpomọkụ, ogige mmepụta ihe (≥10MVA).
Gburugburu Ebe Obibi Mmiri: Ebe ndị dị n'ụsọ oké osimiri, ebe a na-egwupụta ihe (mmanụ anaghị anabata mmiri).
Oke Ihu Igwe: Arụmọrụ kwụsiri ike na -40°C ruo 45°C.
IV. Usoro Ọrụ Nhọrọ
Kọwaa ihe achọrọ:Ụdị ibu (na-aga n'ihu/ujo/nkwekọrịta), gburugburu ebe obibi (iru mmiri/ebe).
Gbakọọ ikike:S = Ike Ibu (kW) / Ihe Ike.
Atụmatụ Ndakọrịta:
Nchekwa ọkụ → Ụdị akọrọ (usoro SCB)
Ike/voltaji dị elu → Mmanụ e mikpuru (usoro S13-M)
Uru Ọnụego:Ogologo oge → Ụdị Akọrọ (TCO dị ala); obere oge → Mmanụ e mikpuru (CAPEX dị ala).
V. Usoro na Ihe Mmepụta Ihe Ọhụrụ
Ụdị Akọrọ:
Nlekota anya nke ọma: ihe mmetụta IoT nwere ike ime (dịka ọmụmaatụ, Siemens CoolBlue).
Voltaji Dị Elu: Ụdị nnwale 66kV maka ugbo ikuku dị n'ụsọ oké osimiri.
Mmanụ e mikpuru n'ime mmiri:
Mmelite Gburugburu Ebe Obibi: β-mmanụ (ebe ọkụ ≥300°C) na-anọchi mmanụ mineral.
Nhazi dị obere: Tankị corrugated emechiri emechi (15% obere akara).
Mmechi
Transformers nke ụdị akọrọ na nke mmanụ mikpuru na-arụkọ ọrụ dịka ngwọta ndị ọzọ. Site na iwu siri ike (dịka ọmụmaatụ, EU Tier 3), ụdị akọrọ na-achịkwa ngalaba azụmaahịa, ebe mmanụ mikpuru ka dị mkpa maka akụrụngwa ike. Maka nhọrọ kacha mma, hazie nkọwapụta teknụzụ na ọnụ ahịa okirikiri ndụ.