Otu esi agbakọ ọkwa ibu kW nke Transformer 1000kVA dabere na Ike Factor

 

Na ụdị ochieTransformer 1000kVAUgbu a, onye na-eji ibu dị ihe dị ka 200kW, transformer a ọ ga-enwe ike ịnabata mmụba nke ọchịchọ ma ọ bụrụ na anyị na-eme atụmatụ itinye ibu ọhụrụ nke ihe dị ka 600kW? Ajụjụ a na-elekwasị anya n'otu echiche dị mkpa: mmekọrịta na ọdịiche dị n'etiti kVA na kW.

 

 

Mmekọrịta na ọdịiche dị n'etiti kVA na kW

 

kVA (kilovolt-ampere) bụ nkeji nke ike pụtara ìhè, ebe kW (kilowatt) na-anọchite anya nkeji nke ike ọrụ. Na mgbakwunye na ike pụtara ìhè na ike ọrụ, enwere ike mmeghachi omume, nke a tụrụ na kvar (kilovar).

 

Kedu ihe dị iche n'etiti ike na-arụ ọrụ, ike na-emegharị ahụ, na ike a na-ahụ anya?

 

Ike Ọrụ: A tụrụ ya na watts (W), ọ na-anọchite anya ike e riri ma ọ bụ ọrụ bara uru nke sekit mere (dịka ọmụmaatụ, ikpo ọkụ, ọkụ).

 

Ike Mmeghachi Omume: A tụrụ ya na volt-amperes reactive (VAR), ọ na-akwado ubi magnetik n'ime ibu inductive (dịka ọmụmaatụ, moto) mana ọ naghị arụ ọrụ nke ọma. Dịka ọmụmaatụ, ọ bụrụ na ngwaọrụ eletriki nwere capacitors ma ọ bụ coils, ihe ndị a ga-agba chajị ma na-apụ mgbe niile ka ngwaọrụ ahụ na-arụ ọrụ. Ebe ọ bụ na capacitors/coils anaghị eri ike eletrik n'ezie n'oge usoro chajị/ịhapụ a, a na-akpọ ike metụtara ya ‌ike reactive‌.

 

Ike Pụrụ Iche: A tụrụ ya na volt-amperes (VA), ọ bụ njikọta nke ike na-arụ ọrụ na nke na-emeghachi omume, nke na-anọchite anya ike zuru oke dị na sekit. Isi iyi ike (nke na-abụkarị transformer ma ọ bụ jenerato) aghaghị inye ọ bụghị naanị ike na-arụ ọrụ kamakwa ike na-emeghachi omume na ngwaọrụ eletriki. Nke a bụ n'ihi na, ọ bụ ezie na capacitors dị na ngwaọrụ ahụ anaghị eri ike na-arụ ọrụ, chaja na mwepụ ha na-aga n'ihu ka chọrọ ka isi iyi ike kenye akụkụ nke ikike ya iji kwado usoro a.

 

Mgbe anyị mechara ka echiche ndị a doo anya, anyị nwere ike inyocha mmekọrịta ha ugbu a, nke na-eduga anyị na echiche dị oke mkpa ọzọ: ihe ike. Oke ike ọrụ nke isi iyi ike nwere ike inye dabere kpọmkwem na ihe ike.

 

Gịnị bụ ike factor?

 

Ihe ike (cosΦ) bụ oke nke ike na-arụ ọrụ (P) na ike a na-ahụ anya (S):

 

Dịka ọmụmaatụ, transformer 1000kVA nwere ike inye ‌600kW‌ nke ike na-arụ ọrụ mgbe ihe ike (cosφ) bụ 0.6, ebe ọ nwere ike iwepụta ‌900kW‌ nke ike na-arụ ọrụ mgbe ihe ike na-abawanye ruo 0.9.

 

Ọ bụrụ na ọnụ ahịa ọkụ eletrik dị $1 kwa kilowatt-hour (kWh), transformer nke na-arụ ọrụ na ike nke 0.6 nwere ike ịkpata ego akụ na ụba nke $600/hour. Mgbe ike ahụ ka mma ruo 0.9, otu transformer ahụ nwere ike ịmepụta ¥900/hour na ego -45. Ọ bụ ezie na uru ego nke imeziwanye ike pụtara ìhè, ihe ọ pụtara na teknụzụ sara mbara (dịka ọmụmaatụ, imeziwanye nkwụsi ike grid na ibelata mfu ike) gafere uru ndị a ozugbo.

 

Kedu kilowatts (kW) ka transformer 1000kVA nwere ike ịkwado?

 

 

Site na ihe ọmụma ntọala e guzobere n'elu, anyị nwere ike ịza ajụjụ bụ isi nke isiokwu a n'ụzọ doro anya na nke ziri ezi.

 

A na-atụ ikike nke transformer na kVA (kilovolt-amperes)‌, ebe a na-atụ ike nke akụrụngwa eletriki na kW (kilowatts). Isi ihe dị iche bụ na ịgbakọ ike na-arụ ọrụ (kW) nke ngwaọrụ chọrọ ịgbakọ ike ya doro anya (kVA) site na ‌ike factor (cosφ)‌. Dịka ọmụmaatụ, transformer 1000kVA nwere ike inye naanị mmepụta ibu zuru oke nke ‌1000kW‌ mgbe ọ na-arụ ọrụ na ‌ike factor nke ‌1.0‌. Agbanyeghị, iru ọnọdụ zuru oke a (PF = 1.0) bụ ihe na-agaghị ekwe omume na ngwa n'ezie.

 

 

 

N'oge nhazi, ọ bụrụ na anyị etinye ụgwọ ihe ike iji nweta ihe ike nke 0.95, a ga-agbakọ mmepụta ike na-arụ ọrụ nke transformer dị ka 1000 × 0.95 = 950kW. Ọkwa Dị Mkpa: Ụlọ ọrụ ike na-enye iwu ka ihe ike (PF) nke ≥0.9‌ zere ntaramahụhụ; agbanyeghị, ịgafe ‌PF = 1.0‌ nwere ike ibute mmụba voltaji sistemụ ma mebie nkwụsi ike grid‌.

 

ATransformer 1000kVANa mbụ, ọ na-enye ibu ọkụ eletrik 200kW. Mgbe etinyere ibu ọhụrụ 600kW, mkpokọta ike ọrụ ruru ‌800kW‌, nke ka dị n'ime oke ọrụ nchekwa nke transformer ahụ.

 

Ya mere, aTransformer 1000kVANa mbụ, inye 200kW nke ibu eletriki nwere ike ịrụ ọrụ ogologo oge ọbụlagodi mgbe etinyere ibu 600kW ọhụrụ (ngụkọta 800kW), ma ọ bụrụhaala na emelitere ike ahụ ka ọ dị elu.