Ahịa transformer traction zuru ụwa ọnụ ga-agafe $12B site na 2025, ebe China na-enye aka karịa 40% ka ihe ọhụrụ teknụzụ na-agbanwe ụlọ ọrụ ahụ
Ndị na-agbanwe ụgbọala na-arụ ọrụ dị ka akụrụngwa bụ isi nke sistemụ ike traction, na-arụ ọrụ atọ dị mkpa:mgbanwe ike, iwu voltaji, na nchedo nkewapụIsiokwu a na-enyocha otu ha si eme ka ọrụ ụgbọ okporo ígwè dị elu, ụgbọ okporo ígwè okpuru ala, na sistemụ maglev rụọ ọrụ nke ọma site na ụkpụrụ teknụzụ, ihe ọhụrụ, na ngwa.
I. Mgbanwe: Site na Ugboro Ahịrị ruo na Transformers Elektrọniki Ike
1. Mmachi nke Transformers Omenala
Nha buru ibu: Na-ejide ihe karịrị 30% nke oghere ụgbọ ala dị n'okpuru, na-egbochi ikike/ọsọ nke ndị njem
Ụlọ arụmọrụ dị elu: Mfu ike 5-8%, nke ka njọ na obere ọsọ
Ọrụ otu: Enweghị ike iweghachite ike brek regenerative
2. Ihe ndị e mere na Power Electronic Transformers (PET)
Ụlọ Ọrụ CRRC Zhuzhou mepụtaraPET 25kV mbụ n'ụwa na 2023, na-enweta:
Mbelata ibu: obere 20%, ọkụ 15% (otu ikike ahụ)
Arụmọrụ dị elu: 98.5% arụmọrụ, 40% mbelata mfu na-enweghị ibu
Njikwa amamịghe: Modulu IGBT (6.5kV/2kHz) na-enye ohere ịgbanwe ike n'oge dị adị
II. Ụdị Isi na Ntụnyere Teknụzụ

III. Teknụzụ Kachasị Elu Na-akwalite Mgbanwe
1. Mgbanwe Ugboro Dị Elu na Ihe Onwunwe
Isi amorphous: Mfu 70% dị ala na-enweghị ibu (ọrụ Jinpan Tech metro)
Ngwaọrụ SiC/GaN: Ugboro mgbanwe 10kHz, obere 30% jụrụ oyi
Epoxy nke Nano gbanwere: Nguzogide mgbawa dị elu nke 50%, ndụ awa 400k
2. Sistemụ O&M Smart
DGA dị n'ịntanetị: >95% izi ezi nke amụma mmejọ
Ejima dijitalụ: Siemens TrafoStar™ belatara ọnụ ahịa O&M site na 40%
3. Imegharị Ike Mmegharị
Mgbanwe nzaghachi: Weghachite ike brek na grid (Shanghai Metro Line 3 na-azọpụta 15%)
Mkpọchi mberede: 110V →1200V ndị na-agbanwe ihe mgbakwụnye maka mgbake ọdịda (Sistemụ 53kW nke Guangyi Electric)
IV. Ngwọta Dabere na Ihe Omume
1. Njem ụgbọ okporo ígwè dị elu
Ihe achọrọ: Ịkwụsi ike na >300km/h
Ngwọta: Transformer nke e ji mmanụ mee + ihe ndozi dị iche iche na-agbanwe agbanwe
Ọnọdụ: Ụgbọ oloko Fuxing na-eji windings abụọ nkewa (90% harmonic suppression)
2. Ike Mberede Metro
Ihe achọrọ: Nnapụta onwe onye n'oge ọdịda
Ngwọta: DC110V→DC1200V ihe ntụgharị nkwalite
Nkọwapụta: 52.8kW/25s + 26.4kW/60s karịrị akarị
Ikpe: Shanghai Metro Lines 3/4 nwetara "mgbake na-enweghị ike mpụga"
3. Ụgbọ okporo ígwè Maglev na Intercity
Ihe achọrọ: Ike dị elu na nzaghachi
Ngwọta: Teknụzụ PETT
Ihe nlereanya CRRCIke: 2.5kVA/kg