+86 18068001229 Nhazi na Nhazi Nhazi nke Amorphous Alloy Transformer (JZP Technical Perspective)
Amorphous Alloy Transformers, nke ụlọ ọrụ dịkaỤlọ Ọrụ Ahụike Ọha, na-anọchite anya ọganihu mgbanwe na Nkesa Ike teknụzụ. Nhazi pụrụ iche ha na-eji ihe ndị dị n'ime alloys metal amorphous eme ihe iji nweta arụmọrụ na nkwado na-enweghị atụ. N'okpuru ebe a bụ nkọwa zuru ezu nke ihe mejupụtara ha na ihe ọhụrụ nhazi ha, na-elekwasị anya na ngwọta injinia JZP.
1. Isi Nhazi: Isi Ihe Dị Mkpa n'Ịrụ Ọrụ;
Isi ihe amorphous alloy bụ ihe na-akọwapụta mgbanwe nke JZP. N'adịghị ka isi ihe ndị e ji ígwè silicon eme, JZP na-eji ya eme ihe. rịbọn amorphous dị gịrịgịrị(ọkpụrụkpụ Ọdịdị atọm na-abụghị kristal;
Ribọn ndị a bụ:
A na-emepụta ya site na ịgbaze agbazeJZP na-eji usoro imechi ngwa ngwa emepụta rịbọn ndị nwere obere kristal, na-ahụ na hysteresis dị ala na mfu ọkụ eletrik.
A merụọ ahụ ka ọ bụrụ ọdịdị toroidal: A na-ejikọta isi ya site na iji ribọn na-agbagharị agbagharị mgbe niile ka ọ bụrụ obere nhazi mechiri emechi. Nke a na-ebelata ntapụ mmiri magnetik ma na-eme ka arụmọrụ ike dịkwuo mma ruo 80% ma e jiri ya tụnyere transformers nkịtị
A na-ejikọta ya na boron-silicon alloys: JZP na-eme ka nhazi alloy ahụ dịkwuo mma (dịka ọmụmaatụ, Fe₇₈B₁₃Si₉) iji nweta Njupụta nke oke mmiri nke 1.5–1.8 T, na-enye ohere ka obere olu isi dị obere ghara imebi arụmọrụ
Ihe ọhụrụ nke JZP:
"Mgbanaka Mgbakwunye Ọtụtụ-Layer" nke e ji ikike ikike nweta: Na-ebelata nrụgide dị n'ime rịbọn, na-eme ka nkwụsi ike nke igwe dịkwuo mma n'oge a na-agbagharị agbagharị.
Nhazi Mgbanwe Mgbanwe: Na-agbanwe usoro ihe dị mkpa iji kwekọọ na mgbanwe ibu, na-ebelata mfu ọrụ site na 15%
2. Ndọtị: Nkọcha na Ịdịgide;
A na-emepụta windings JZP maka ike dị elu na iguzogide okpomọkụ:
Ọla kọpa/aluminom Conductor: Mkpọchi ọla kọpa dị ọcha nke ukwuu (99.99%) na-ebelata mfu ndị na-eguzogide ọgwụ. Maka ngwa ndị na-adịghị oke ọnụ ahịa, JZP na-enye windings aluminom nwere arụmọrụ nhata
Ntinye ihe mkpofuA na-etinye windings n'ime resin epoxy n'okpuru ikuku iji wepụ akpa ikuku, na-eme ka mkpuchi ahụ guzosie ike n'okpuru oke okpomọkụ
Nhazi Njikọ Dyn11: Nhazi a na-agbagharị agbagharị a na-egbochi mgbanwe harmonic (dịka ọmụmaatụ, harmonic nke atọ) site na ịhazi mgbanwe nke usoro, dị oke mkpa maka grid ụlọ ọrụ mmepụta ihe nwere ibu na-abụghị ahịrị
Mmezi JZP:
Teknụzụ Ngbanwe Na-agbanwe agbanwe: Na-eji ogwe aka robot nke nwere njikwa nrụgide nke AI na-eduzi iji rịbọn ikuku na-enweghị obere mgbawa, na-agbatị ndụ ọrụ site na 30%
3. Mkpuchi na Njikwa Okpomọkụ;
Akwa mkpuchi siri ikeJZP na-ewe ọrụ akwụkwọ nomexna ihe nkiri polyesteriji kewapụ windings site na isi, nke a tụrụ maka ike dielectric 35 kV/mm.
Nhazi Tankị Jupụtara Mmanụ:
Ihe mkpuchi e mechiri emechi: Na-egbochi mmiri ịbanye na oxidation, na-agbaso ụkpụrụ IEC 60599
Ntutu oyiNku aluminom etinyere n'ime tankị ahụ na-eme ka okpomọkụ ghara ịpụ apụ, na-ebelata okpomọkụ ọrụ site na 10–15°C
Ọganihu JZP:
Mkpuchi Ọgwụgwọ Onwe Onye: Resin epoxy nke e ji nanoparticle mee ka ọ dịkwuo mma na-arụzi obere mmebi mkpuchi ahụ n'onwe ya, na-ebelata mkpa mmezi
4. Mgbakọ na Ihe Ịma Aka;
Mgbakọ Isi-na-Ịfegharị: JZP na-eji nkwonkwo ndị e ji laser dụkọtaiji jikọọ rịbọn, belata oghere ikuku na iguzogide magnet.
Mmesi Ike Mekaniki: Okpokoro polima e ji fiberglass mee ka ọ sie ike na-akwado isi ya, na-ebelata ike ọgwụgwụ nke ịma jijiji kpatara.
Ihe ịma aka ndị dị mkpa nke JZP doziri:
Nchacha Ribọn: Mepụtara usoro "tupu nrụgide" iji mee ka rịbọn dịkwuo mfe n'oge eji ya.
Arụmọrụ ọnụ ahịa: Algọridim ịkpụ rịbọn kachasị mma iji belata ihe mkpofu ihe site na 25%
5. Usoro Arụmọrụ na Ngwa
| Paramita | JZP Amorphous Transformer | Transformer Silicon Steel nke ọdịnala |
| Mfu Na-enweghị Ibu | 0.15–0.3 W/kVA | 0.8–1.2 W/kVA |
| Mfu Ibu | 1.2–1.8 W/kVA | 2.5–3.5 W/kVA |
| Arụmọrụ | >98% | 92–95% |
| Ọkwa Mkpọtụ | ≤45 dB | 55–65 dB |
Ngwa:
Grid Smart: Ọ dị mma maka nkesa obodo n'ihi obere mkpọtụ na obere nha.
Ike Mmegharị Ọhụrụ: Na-ejikọta ya na sistemụ anyanwụ/ikuku nke ọma maka mgbanwe DC-AC
Mmechi
Mgbanwe alloy amorphous nke JZP na-egosi njikọta nke sayensị ihe onwunwe na mmepụta dị elu. Site n'ịtụgharị uche na nhazi isi, nkenke ịgbagharị, na njikwa okpomọkụ, JZP ewepụtala akara ọhụrụ na arụmọrụ ike, na-eme ka transformers ndị a dị oke mkpa maka akụrụngwa ike na-adịgide adịgide. Maka nkọwapụta teknụzụ ndị ọzọ, lee akwụkwọ ngwaahịa JZP ma ọ bụ gakwuru ndị otu injinia ha.