Leave Your Message
Ngalaba Akụkọ
Akụkọ Ndị A Mapụtara

Transformer Amorphous Alloy na Silicon Steel Transformer

2025-10-20

Ị ma ihe dị iche n'etiti Amorphous Alloy Transformers na transformers ígwè silicon nkịtị? Dịka onye na-emepụta transformer nke nwere ahụmịhe afọ 15+, JZP na-akọwa ọdịiche dị n'etiti ụdị transformer abụọ a. Ọ bụghị naanị ihe dị iche; ọ bụ ọgụ teknụzụ dị n'etiti arụmọrụ ike, ọnụ ahịa, na usoro ọdịnihu.

 

 

Amorphous Alloy vs. Transformer nkịtị

 

Transformer Silicon Steel nkịtị

Transformers nkịtị nwere isi ihe e ji mpempe akwụkwọ ígwè silicon nke a na-akpọ "cold-rolled", nke a na-ahazi n'ime usoro kristal dị ọcha ma na-adịgide adịgide.

Nhazi a nke ọma na-eme ka ike ndọta dị obere mgbe e tinyere ya n'akụkụ ntụgharị, na-eme ka arụmọrụ ya dị mma. Agbanyeghị, ha ka bụ kristal, magnetization na-erikwa ike, na-emepụta "mfu hysteresis." Ọzọkwa, mpempe ígwè silicon nwere ọkpụrụkpụ ụfọdụ, ebe ndọta ndị ọzọ na-akpali "mfu eddy" n'ime ha, na-eduga na "mfu eddy current," nke a na-akpọ "mfu iron."

 

Amorphous Alloy Transformer

E ji rịbọn amorphous, nke a makwaara dị ka "iko ọla." Nhazi atọm ya dị mgbagwoju anya ma dịkwa mgbagwoju anya. A na-emepụta nhazi a site n'ime ka agbaze okpomọkụ dị oke elu jụọ oyi ngwa ngwa na ọnụego nde ogo kwa sekọnd, usoro pụrụ iche. Nsogbu atọm a dị ogologo na-ebelata mfu hysteresis nke ukwuu; ọkpụrụkpụ ya dị gịrịgịrị na oke iguzogide ya na-ebelata mfu ugbu a.

 

Ntụnyere Arụmọrụ

Nha ntụnyere

Amorphous Alloy Transformer

 

Transformer Silicon Steel nkịtị

 

Nyocha na Nkọwa

 

Mfu Isi

 

Oke Ala Dị Ala

 

Elu

 

Mfu ndị na-enweghị ibu dị ala, na nkezi, 60%-80% karịa ndị yiri ya na S13/S14 silicon steel transformers.

 

Ugbu a enweghị ibu

 

Obere

 

Nnukwu

 

Enwere ike ibelata ọkụ eletrik na-enweghị ibu site na ihe dị ka 40%-80%, nke pụtara na obere mmetụta ike na-emegharị na grid na obere mfu ahịrị.

 

Ọkwa arụmọrụ ike

 

Oke Elu

 

Elu

 

Ndị na-agbanwe agbanwe amorphous na-agbaso ọkọlọtọ arụmọrụ ike nke Klas I nke mba dị mfe, na-anọchite anya arụmọrụ ike kachasị elu ma e jiri ya tụnyere ndị na-agbanwe ígwè silicon (karịsịa Klas nke Abụọ ma ọ bụ Klas nke Atọ).

 

Ọnụ Ego Mmepụta

 

Elu

 

Dị ala

 

Amorphous alloy stripe dị oke ọnụ, siri ike, ma gbajie agbawa, usoro ịkpụcha na ịchacha ihe dịkwa mgbagwoju anya, nke na-eme ka mmepụta ya dị elu karịa ígwè silicon nke nwere otu ikike ahụ site na 20% ruo 35%. Nke a bụ ihe kacha njọ ọ na-akpata.

 

 

Ike Mekaniki

 

Dị ala

 

Elu

Ákwà ígwè amorphous siri ike ma gbajie agbawa, ọ naghịkwa anabata mkpọtụ na mkpọtụ. A ga-akpachara anya nke ọma n'oge njem, ntinye, na obere sekit. Mpempe ígwè silik siri ike karịa ma nwee ike iguzogide mmetụta ka mma.

 

Njupụta nke magnetic flux na-arụ ọrụ

 

Dị ala (1.3-1.5T)

 

Elu (1.6-1.8T)

 

Njupụta nke magnetic flux nke amorphous alloys dị ala, nke pụtara na achọrọ mpaghara cross-sectional buru ibu n'otu ike ahụ, nke nwere ike ibute mmụba dị nta na olu na ibu nke transformer ahụ.

 

Mkpọtụ Ọrụ

 

Obere Elu

 

Dị ala

 

Mmetụta magnetostrictive (obere mgbanwe na nha ihe mgbe e tinyere magnet) nke amorphous alloys na-apụta ìhè karịa nke mpempe ígwè silicon, na-eme ka hum dị elu karịa (ihe dị ka 2-5 dB karịa) n'oge ọrụ. Enwere ike ịchọ njikwa pụrụ iche n'ebe ndị nwere mmetụta mkpọtụ.

 

Arụmọrụ gburugburu ebe obibi

 

Ọ dị mma nke ukwuu

 

Ọ dị mma

Mfu dị oke ala nke na-enweghị ibu pụtara nnukwu nchekwa ike n'oge usoro ndụ niile (afọ 20-30), nke yiri ibelata mwepụta carbon site na tọn ole na ole ma ọ bụ ọbụna tọn iri.

Transformers ígwè silicon nkịtị: Ego mbụ e tinyere obere, mana ọ na-efu ọkụ eletrik dị elu. Mfu ha na-enweghị ibu na-eme awa iri abụọ na anọ kwa ụbọchị, na-eri ọkụ eletrik na-aga n'ihu ma ọ bụrụhaala na transformer ahụ ejikọtara na grid.

 

Mgbanwe Amorphous alloy: Ntinye ego dị elu na mbido, mana ọ dị oke ọnụ ahịa ọkụ eletrik na-arụ ọrụ. Nchekwa ike ha nwere ike ọ gaghị adị oke mkpa n'otu ụbọchị, mana n'ime oge ndụ ha niile (afọ 20-30), nchekwa ahụ nwere ike ịdị oke egwu.

 

Maka ụlọ ọrụ nwere ọtụtụ ngwaahịa Transformer nkesas na ihe ndị dị obere ibu (dịka ụlọ ọrụ grid ike, ebe data, na nnukwu ụlọ ọrụ azụmahịa), uru akụ na ụba nke transformers amorphous na-adọrọ adọrọ nke ukwuu.